The Use of the Tip Stim Glove Device to Achieve Coordinated Movement of the Human Hand
|
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details. |
| ClinicalTrials.gov Identifier: NCT04825405 |
|
Recruitment Status :
Completed
First Posted : April 1, 2021
Last Update Posted : April 1, 2021
|
- Study Details
- Tabular View
- No Results Posted
- Disclaimer
- How to Read a Study Record
| Condition or disease | Intervention/treatment | Phase |
|---|---|---|
| Stroke, Ischemic | Procedure: hand motor coordination in a sitting position after use TipStim Glove | Not Applicable |
To test the effectiveness of the Tip Stim device, each patient received (alternating) both the experimental and control treatments in a specific sequence to assess the coordination of human hand movement and the grip strength. The first therapy with the use of Tip Stim parameters (Ratio current time to pause time: 2 sec :5 sec; Ramp (rise time impulse): 0,3 sec; Frequency: 20 Hz; Pulse width: 300 µs). Another session (putting on the glove without setting any parameters) took place after a week (time to mute the effects of the intervention). The duration of each therapy session is 60 minutes. After the first therapeutic session and after a week, the parameters of movement coordination and hand grip were examined. The study of motor coordination and grip strength was performed in two different starting positions: sitting (no stabilization) (fig. 1) and lying (with stabilization) (fig. 2), and with a different position of the examined upper limb. During the first examination, the subject sat on a treatment table, feet resting on the floor. Upper limb examined in adduction, with bent elbow joint in the intermediate position between pronation and supination of the forearm. In the supine examination, the upper limb was stabilized against the subject's body (adduction in the shoulder joint, flexion in the elbow joint in an intermediate position). In each of the starting positions, first after putting on the glove, the range of passive motion in the radial-wrist joint (flexion and extension) and fingers (global flexion and extension) was measured, then the active movement was measured, in the sequence as above. Eventually, they were asked to make movements as quickly and as fully as possible. Measurement of the grip force with a dynamometer was performed in both analyzed starting positions after testing the ranges of motion and speed/frequency.
The Hand Tutor device and the EH 101 electronic hand dynamometer measuring the strength of the handgrip (measurement error 0.5 kg / 1 lb) were used to test the parameters of motor coordination and grip strength. The Hand Tutor is a device with a rehabilitation program and the ability to measure the range of passive and active movement, deficits of movement (error of measurement, 5 - 10 mm) as well as the speed/frequency of movement (error of measurement, 0,5 cycle/sec.).
| Study Type : | Interventional (Clinical Trial) |
| Actual Enrollment : | 29 participants |
| Allocation: | Randomized |
| Intervention Model: | Crossover Assignment |
| Masking: | None (Open Label) |
| Primary Purpose: | Treatment |
| Official Title: | Influence of the Tested Position and the Use of the TipStim Glove Device on the Improvement of the Hand Motor Coordination After Stroke |
| Actual Study Start Date : | July 10, 2019 |
| Actual Primary Completion Date : | February 14, 2020 |
| Actual Study Completion Date : | February 14, 2020 |
| Arm | Intervention/treatment |
|---|---|
|
Active Comparator: The use of the active Tip Stim device to achieve coordinated of the hand.
Influence of the tested position and the use of the active TipStim Glove device on the improvement of motor coordination and grip force in patients after a stroke.
|
Procedure: hand motor coordination in a sitting position after use TipStim Glove
The next therapy with the use of Tip Stim took place after a week. The duration of each therapy session was 60 minutes. After the first therapy session and after a week, the parameters of movement coordination and handgrip were examined. The study of motor coordination and grip strength was performed in two different starting positions: sitting (no stabilization) and lying (with stabilization), and with a different position of the examined upper limb. The upper limb was examined in adduction, with the bent elbow joint in the intermediate position of the forearm. In each of the starting positions, first, the range of passive motion in the wrist joint (flexion and extension) and fingers (global flexion and extension) was measured, then the active movement was measured, in the sequence as above. Patients were asked to make movements as quickly and as fully as possible. Measurement of the grip force was performed after testing the ranges of motion and speed/frequency.
Other Name: hand motor coordination in a supine position after use TipStim Glove |
|
Placebo Comparator: The use of the passive Tip Stim device to achieve coordinated of the hand.
Influence of the tested position and the use of the passive TipStim Glove device on the improvement of motor coordination and grip force in patients after a stroke.
|
Procedure: hand motor coordination in a sitting position after use TipStim Glove
The next therapy with the use of Tip Stim took place after a week. The duration of each therapy session was 60 minutes. After the first therapy session and after a week, the parameters of movement coordination and handgrip were examined. The study of motor coordination and grip strength was performed in two different starting positions: sitting (no stabilization) and lying (with stabilization), and with a different position of the examined upper limb. The upper limb was examined in adduction, with the bent elbow joint in the intermediate position of the forearm. In each of the starting positions, first, the range of passive motion in the wrist joint (flexion and extension) and fingers (global flexion and extension) was measured, then the active movement was measured, in the sequence as above. Patients were asked to make movements as quickly and as fully as possible. Measurement of the grip force was performed after testing the ranges of motion and speed/frequency.
Other Name: hand motor coordination in a supine position after use TipStim Glove |
- Range of passive movement of the wrist, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the range of passive movement (in mm)
- Range of active movement of the wrist, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the range of active movement (in mm)
- Wrist extension deficit, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the wrist extension deficit, (in mm)
- Wrist flexion deficit, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the wrist flexion deficit, (in mm)
- Maximum range of wrist movement [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the maximum range of movement (in mm)
- Frequncy of wrist movement (flexion to extension), cycle#sec [ Time Frame: up to 1 week ]The Hand Tutor allows measurement of the speed or frequency (i.e., the number of cycles per sec.)
- Assessment of the grip strength [ Time Frame: up to 1 week ]A manual electronic dynamometer (EH 101) was used for grip strength measurement (kg)
- Range of passive movement of the fingers, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the range of fingers passive movement (in mm)
- Range of active movement of the fingers, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the range of fingers active movement (in mm)
- Fingers extension deficit, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the fingers extension deficit, (in mm)
- Fingers flexion deficit, mm [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the fingers flexion deficit, (in mm)
- Maximum range of fingers movement [ Time Frame: up to 1 week ]The Hand Tutor allows measuremnt of the maximum range of movement (in mm)
- Frequncy of fingers movement (flexion to extension), cycle#sec [ Time Frame: up to 1 week ]The Hand Tutor allows measurement of the speed or frequency (i.e., the number of cycles per sec.)
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.
| Ages Eligible for Study: | 42 Years to 89 Years (Adult, Older Adult) |
| Sexes Eligible for Study: | All |
| Accepts Healthy Volunteers: | No |
Inclusion Criteria:: 1) patients with hemiparesis after 5 to 7 weeks after stroke; 2) no severe deficits in communication, memory, or understanding what can impede proper measurement performance; 3) at least 40 years of age; 4) maximum 89 years of age.
-
Exclusion Criteria:1) stroke up to two weeks after the episode, 2) acute polyneuropathy and damage to peripheral nerves, 3) lack of trunk stability, 4) no wrist and hand movement, 5) hypersensitivity to electrical stimulation, 6) metal implants in the hand, cardiac dysfunction, epilepsy, 7) decorations on the fingers, 8) high or very low blood pressure, 9) dizziness , malaise of the respondents.
-
To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.
Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT04825405
| Poland | |
| Anna Olczak | |
| Warsaw, Masovian District, Poland, 04-141 | |
| Principal Investigator: | Anna Olczak, PhD | Military Institute of Medicine |
| Responsible Party: | Anna Olczak, PhD; Senior Specjalit of the Rehabilitation Clinc, Military Institute of Medicine, Poland |
| ClinicalTrials.gov Identifier: | NCT04825405 |
| Other Study ID Numbers: |
6/KRN/2019 |
| First Posted: | April 1, 2021 Key Record Dates |
| Last Update Posted: | April 1, 2021 |
| Last Verified: | March 2021 |
| Individual Participant Data (IPD) Sharing Statement: | |
| Plan to Share IPD: | No |
| Studies a U.S. FDA-regulated Drug Product: | No |
| Studies a U.S. FDA-regulated Device Product: | No |
|
Tip Stim Glove device motor coordination grip strength passive stabilization stroke |
|
Stroke Ischemic Stroke Cerebrovascular Disorders Brain Diseases |
Central Nervous System Diseases Nervous System Diseases Vascular Diseases Cardiovascular Diseases |