The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Know the risks and potential benefits of clinical studies and talk to your health care provider before participating. Read our disclaimer for details. |
| ClinicalTrials.gov Identifier: NCT04660136 |
|
Recruitment Status :
Recruiting
First Posted : December 9, 2020
Last Update Posted : December 10, 2020
|
- Study Details
- Tabular View
- No Results Posted
- Disclaimer
- How to Read a Study Record
Purpose:
There is no previous contrast enhanced ultrasound (CEUS) study for pediatric Crohn disease patients. There are adult studies which included adolescent patients. More pediatric patients have been diagnosed as Crohn disease due to dietary change in Korea and it would be cost effective and clinically useful if CEUS was available in Crohn disease patients as a diagnostic and follow up tool.
Objective, hypothesis:
- Primary Objective To prospectively examine the feasibility of Contrast Enhanced Ultrasound (CEUS) in the assessment of Crohn's disease (CD) using endoscopy as a reference standard Feasibility was defined as the successful examination in over 90% of included patients.
- Secondary Objective To reaffirm the dosing and safety of ultrasound contrast agent and assess the image quality of the CEUS
Methodology:
This is a single center prospective observational study. Pediatric patients who was first diagnosed as CD with colonoscopy are enrolled in this study, The disease activity, clinical symptoms are also investigated. Within a period of maximally two weeks from the reference ileocolonoscopy and before any therapeutic changes, the patients underwent CEUS. CEUS was performed by one different pediatric radiologist, masked to all other imaging, endoscopic, and clinical data, except diagnosis of CD. CEUS was analyzed using quantification soft-ware (Vuebox), based on ROI at the most enhanced part of the bowel wall, quantitative parameters were calculated. After the first CEUS, CEUS would be performed after one year.
Pediatric population , 20 patients.
Imaging procedure:
Within a period of maximally two weeks from the reference ileocolonoscopy and before any therapeutic changes, the patients underwent CEUS on the same day. All studies started with a grey scale US examination to find the terminal ileum and assess wall thickness, induration of surrounding fatty tissue and enlarged lymphnodes. Stenosis and length of the pathologic bowel wall was estimated, as well as complications such as abscess formation and fistulae. The thickest segment of the terminal ileum was identified and used to perform analysis of contrast enhancement. The investigators injected the second generation, ultrasonic contrast agent (SonoVue, Bracco, Milan, Italy) as a bolus of 0.03 ml/kg through a three-way 20-gauge catheter in an antecubital vein, followed by a bolus of 5 ml saline solution (0.9% NaCl).CEUS was performed with a 7.5MHz linear probe and contrast-tuned technology, based on allow mechanical index and a real-time scan to ensure the preservation of the contrast agent. A low acoustic power setting was used, expressing a low mechanical index (MI), 0.09-0.14, of a 7.5 MHz linear probe. To assess the vascularization of the involved bowel loop, the contrast uptake over quantitative analysis of the brightness intensity was measured over a period of 40 s, in regions of interest (ROI) located manually in the intestinal wall with at least 2 cm2. The investigators used a dedicated software (Vuebox) and a time-intensity curve was automatically acquired. The quantitative measurement of the contrast uptake was obtained as the difference between the maximum enhancement value and the baseline value before the arrival of contrast.
Analysis, evaluation, reporting of results:
-
data acquisition: age, sex, initial treatment,
- define involved bowel segment (5 segments: the terminal ileum, right colon (cecum and ascending), transverse colon, left colon (descending and sigmoid) and rectum), Gray scale US parameters identification of the terminal ileum, wall thickness measurement at the maximal diameter of the affected terminal ileum (pathological mural thickening defined as a wall thickness above 3 mm), evaluation of the affected bowel length, stratified wall appearance, perivisceral findings such as creeping fat and stenosis, fistula or abscess CEUS quantitative parameters, Numerous CEUS quantitative perfusion parameters can be derived from this curve. FT indicates fall time; mTTl, mean local transit time; PE, peak enhancement; RT, rise time; TTP, time to peak; WiAUC, wash-in area under the curve; WiR, wash-in rate; WiWoAUC, wash-in 1 wash-out area under the curve; WoAUC, wash-out area under the curve; and WoR, wash-out rate.
Clinical and laboratory parameters (CDAI,, CRP, ESR and Calprotectin)
- interpretation: independent interpretation of CEUS with colonoscopy as gold standard
-
outcome assessment
- Successfully complete event number without adverse events
- Treatment response: assessed by pediatric gastroenterologist by lab results, colonoscopy results, and patient symptom improvement
| Condition or disease | Intervention/treatment | Phase |
|---|---|---|
| Crohn's Disease in Pediatric Patient | Biological: contrast enhanced ultrasound | Phase 4 |
| Study Type : | Interventional (Clinical Trial) |
| Estimated Enrollment : | 20 participants |
| Allocation: | N/A |
| Intervention Model: | Single Group Assignment |
| Masking: | None (Open Label) |
| Primary Purpose: | Diagnostic |
| Official Title: | Usefulness of Contrast-enhanced Ultrasound (CEUS) in Crohn's Disease Pediatric Patients |
| Actual Study Start Date : | December 1, 2020 |
| Estimated Primary Completion Date : | March 2023 |
| Estimated Study Completion Date : | March 2023 |
| Arm | Intervention/treatment |
|---|---|
| Experimental: CEUS |
Biological: contrast enhanced ultrasound
We injected the second generation, ultrasonic contrast agent (SonoVue, Bracco, Milan, Italy) as a bolus of 0.03 ml/kg through a three-way 20-gauge catheter in an antecubital vein, followed by a bolus of 5 ml saline solution (0.9% NaCl).CEUS was performed with a 7.5MHz linear probe and contrast-tuned technology, based on allow mechanical index and a real-time scan to ensure the preservation of the contrast agent. A low acoustic power setting was used, expressing a low mechanical index (MI), 0.09-0.14, of a 7.5 MHz linear probe. |
- feasibility of Contrast Enhanced Ultrasound (CEUS) in the assessment of Crohn's disease (CD) using endoscopy as a reference standard [ Time Frame: 1 day ]Feasibility was defined as the successful examination in over 90 percent of included patients.
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.
| Ages Eligible for Study: | 2 Years to 18 Years (Child, Adult) |
| Sexes Eligible for Study: | All |
| Accepts Healthy Volunteers: | No |
Inclusion Criteria:
- Patients who are under the age of 18
- Patients who have Crohn's disease with colonoscopy from 2020.01-2022.02 in Severance Children Hospita
Exclusion Criteria:
- Patients who are over the age of 18 and under the age of two
- Patients who have other bowel disease or mass than Crohn's disease
- High allergic sensitivity to Sonovue injection agent or sulfur hexafluoride
- Patients who have right to left shunt, pulmonary hypertension, or systemic hypertension
- Patients who have end stage renal or liver disease or septic shock
To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.
Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT04660136
| Contact: Haesung Yoon | +82-10-9204-7549 | saydivine@yuhs.ac |
| Korea, Republic of | |
| Severance Hospital | Recruiting |
| Seoul, Korea, Republic of | |
| Contact: Haesung Yoon +82-10-9204-7549 saydivine@yuhs.ac | |
| Principal Investigator: | Haesung Yoon | Severance Hospital |
| Responsible Party: | Yonsei University |
| ClinicalTrials.gov Identifier: | NCT04660136 |
| Other Study ID Numbers: |
4-2020-1010 |
| First Posted: | December 9, 2020 Key Record Dates |
| Last Update Posted: | December 10, 2020 |
| Last Verified: | December 2020 |
| Individual Participant Data (IPD) Sharing Statement: | |
| Plan to Share IPD: | No |
| Studies a U.S. FDA-regulated Drug Product: | No |
| Studies a U.S. FDA-regulated Device Product: | No |
|
Crohn Disease Inflammatory Bowel Diseases Gastroenteritis |
Gastrointestinal Diseases Digestive System Diseases Intestinal Diseases |