Non-Invasive Monitoring of Partial Pressure of Carbon Dioxide in Mechanically Ventilated Preterm Infants
|
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details. |
| ClinicalTrials.gov Identifier: NCT03758313 |
|
Recruitment Status :
Completed
First Posted : November 29, 2018
Last Update Posted : August 17, 2021
|
- Study Details
- Tabular View
- No Results Posted
- Disclaimer
- How to Read a Study Record
In mechanically ventilated preterm infants, the ability to monitor carbon dioxide partial pressure (pCO2) values is indispensable. The gold standard for pCO2 measurement is from an arterial blood sample (paCO2). This has two drawbacks: firstly, it requires an arterial line and, secondly, it does not provide the clinicians with a continuous measurement. At present, two alternative pCO2 monitoring systems are available in the field of neonatal intensive care medicine: end-tidal CO2 (etCO2) capnography and transcutaneous CO2 (tcCO2) measurements. Both methods have disadvantages including potential technical errors as well as pathologies that may reduce reliability as a surrogate for blood gas analysis (BGA). In particular, conventional side-stream etCO2 capnography underestimates pCO2 in presence of a tube leakage, which is a common occurrence in ventilated preterm infants where only tubes without cuff are used. Distal etCO2 (detCO2) by means of a double lumen endo-tracheal tube may solve the problem of unreliable etCO2 values in the presence of tube leakage.
The aim of this study is to compare the agreement, precision and repeatability of the distal etCO2-measurement technique described by Kugelman et al. with respect to paCO2 and tcCO2 in mechanically ventilated preterm infants. Since ventilation strategies and pCO2 limits may vary among different centers, this study helps to determine which non-invasive CO2 monitoring system (detCO2 or tcO2) is more suitable in terms of applicability and reliability in preterm infants at our neonatal intensive care units.
| Condition or disease | Intervention/treatment |
|---|---|
| Preterm Infant | Other: CO2 measurements |
Background: In mechanically ventilated preterm infants, the ability to monitor carbon dioxide partial pressure (pCO2) values is indispensable. The gold standard for pCO2 measurement is from an arterial blood sample (paCO2). This has two drawbacks: firstly, it requires an arterial line and, secondly, it does not provide the clinicians with a continuous measurement. At present, two alternative pCO2 monitoring systems are available in the field of neonatal intensive care medicine: end-tidal CO2 (etCO2) capnography and transcutaneous CO2 (tcCO2) measurements. Both methods have disadvantages including potential technical errors as well as pathologies that may reduce reliability as a surrogate for blood gas analysis (BGA). In particular, conventional side-stream etCO2 capnography underestimates pCO2 in presence of a tube leakage, which is a common occurrence in ventilated preterm infants where only tubes without cuff are used. Distal etCO2 (detCO2) by means of a double lumen endo-tracheal tube may solve the problem of unreliable etCO2 values in the presence of tube leakage.
Several studies compared etCO2 and tcCO2 to paCO2, simultaneously. A comparison study of etCO2 and tcCO2 in a cohort of critically ill children did not reveal significant differences in the absence of severe pulmonary parenchymal disease. Tobias et al compared etCO2 and tcCO2 in a cohort of pediatric intensive care patients with respiratory failure and found tcCO2 measurements to be more accurate. In a cohort of ventilated newborns, tcCO2 monitoring was generally more precise than etCO2 during neonatal transport to monitor ventilation. In a more recent study restricted to a cohort of postsurgical neonates without lung disease, etCO2 underestimated paCO2 more than tcCO2 but provided greater precision over paCO2, however it was less accurate at smaller tidal volumes. These studies have in common that the adapter of the pCO2 analyzer was attached in-line and proximal to the endotracheal tube.
Aim of the study: The aim of this study is to compare the agreement, precision and repeatability of the distal etCO2-measurement technique described by Kugelman et al. with respect to paCO2 and tcCO2 in mechanically ventilated preterm infants. Since ventilation strategies and pCO2 limits may vary among different centers, this study helps to determine which non-invasive CO2 monitoring system (detCO2 or tcO2) is more suitable in terms of applicability and reliability in preterm infants at our neonatal intensive care units.
| Study Type : | Observational |
| Actual Enrollment : | 27 participants |
| Observational Model: | Cohort |
| Time Perspective: | Prospective |
| Official Title: | Non-Invasive Monitoring of Partial Pressure of Carbon Dioxide in Mechanically Ventilated Preterm Infants |
| Actual Study Start Date : | November 1, 2018 |
| Actual Primary Completion Date : | September 26, 2020 |
| Actual Study Completion Date : | September 30, 2020 |
- Other: CO2 measurements
Distal etCO2, tcCO2 and paCO2 values will be recorded simultaneously in ventilated preterm infants. We will measure etCO2 in a distal position using a double lumen tube connected to an external side-stream capnometer.
- Carbon Dioxide in Mechanically Ventilated Preterm Infants [ Time Frame: 48 hours ]partial pressure of carbon dioxide
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.
| Ages Eligible for Study: | Child, Adult, Older Adult |
| Sexes Eligible for Study: | All |
| Accepts Healthy Volunteers: | No |
| Sampling Method: | Non-Probability Sample |
Inclusion Criteria:
- Preterm infants with a current body weight between 1000 g and 3000 g who require intubation.
- Signed informed consent from parents or legal guardians.
- Expected to provide at least three measurements of paCO2 and detCO2.
Exclusion Criteria:
- Infants with known congenital anomalies of the heart and/or lung.
- Need for high frequency oscillation.
- Parents or legal guardians deny informed consent.
To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.
Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT03758313
| Austria | |
| Department of Pediatrics, Division of Neonatology, Pediatric Intensive Care and Neuropediatrics, Medical University of Vienna | |
| Vienna, Austria, 1090 | |
| Principal Investigator: | Tobias Werther, PhD | Medical University Vienna |
Publications automatically indexed to this study by ClinicalTrials.gov Identifier (NCT Number):
| Responsible Party: | Tobias Werther, Dr., Medical University of Vienna |
| ClinicalTrials.gov Identifier: | NCT03758313 |
| Other Study ID Numbers: |
1173/2018 |
| First Posted: | November 29, 2018 Key Record Dates |
| Last Update Posted: | August 17, 2021 |
| Last Verified: | August 2021 |
| Individual Participant Data (IPD) Sharing Statement: | |
| Plan to Share IPD: | Undecided |
| Studies a U.S. FDA-regulated Drug Product: | No |
| Studies a U.S. FDA-regulated Device Product: | No |
|
Premature Birth Obstetric Labor, Premature Obstetric Labor Complications Pregnancy Complications |