A Prospective Evaluation of the Catheter Science C3 "Umbrella Catheter."
|
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details. |
| ClinicalTrials.gov Identifier: NCT03353571 |
|
Recruitment Status : Unknown
Verified November 2017 by Dr. Gaines W. Hammond Jr. MD FACS, Hammond, Gaines W., Jr., M.D. FACS.
Recruitment status was: Recruiting
First Posted : November 27, 2017
Last Update Posted : November 27, 2017
|
- Study Details
- Tabular View
- No Results Posted
- Disclaimer
- How to Read a Study Record
| Condition or disease | Intervention/treatment | Phase |
|---|---|---|
| Urinary Retention Urinary Bladder, Neurogenic Intermittent Catheterization | Device: C3 "UMBRELLA CATHETER" | Not Applicable |
Interventional (clinical trial): Participants are assigned prospectively to an intervention or interventions according to a protocol to evaluate the effect of the intervention(s) on biomedical or other health related outcomes.
This single arm, prospective study is designed to produce valid scientific evidence regarding:
- Safety and efficacy of the Catheter Science C3 "Umbrella Catheter" in establishing urinary drainage and allowing the control of micturition when indwelling for up to 7 days.
- The reduction in Catheter Acquired Urinary Tract Infection (CAUTI)
A single arm study design was chosen because there is no alternative treatment to serve as an appropriate control. The C3 catheterizes the bladder with engagement into the bladder neck under the control of the patient or care giver. A Foley catheter, a pre- amendment device, was considered for a control treatment. However, although a Foley catheter is used to establish urinary drainage with close to 100% efficacy, it does not restore voiding function like the C3, and severely impairs activities of daily life.
The intrinsic design flaws of a Foley catheter traversing thru the urinary passage which violates the anatomical protective points which help to avoid bacterial contamination. The distal 1/3 portion of the urethra in females is commonly colonized with bacteria. Standard Catheter technique traverses from the outside into the entire length of the urethra to drain the bladder. The standard self catheter flow characteristics are impacted due to the placements of the "eyes" to the catheter lumen. The C3 lumen is open in line with the flow.
| Study Type : | Interventional (Clinical Trial) |
| Estimated Enrollment : | 50 participants |
| Allocation: | N/A |
| Intervention Model: | Single Group Assignment |
| Intervention Model Description: | Safety and efficacy of the Catheter Science C3 "Umbrella Catheter" in establishing urinary drainage and allowing the control of micturition when indwelling for up to 7 days. The reduction in Catheter Acquired Urinary Tract Infection (CAUTI) A single arm study design was chosen because there is no alternative treatment to serve as an appropriate control. The C3 catheterizes the bladder with engagement into the bladder neck under the control of the patient or care giver. A Foley catheter, a pre- amendment device, was considered for a control treatment. However, although a Foley catheter is used to establish urinary drainage with close to 100% efficacy, it does not restore voiding function like the C3, and severely impairs activities of daily life. |
| Masking: | None (Open Label) |
| Primary Purpose: | Other |
| Official Title: | A Prospective Evaluation of the Catheter Science C3 "Umbrella Catheter" for Patients With Urinary Retention Due to Bladder Dysfunction (C3 Catheter Study) |
| Actual Study Start Date : | August 31, 2017 |
| Estimated Primary Completion Date : | March 2018 |
| Estimated Study Completion Date : | March 2018 |
| Arm | Intervention/treatment |
|---|---|
|
C3 PATIENT PARTICIPANTS
This single arm prospective study is designed to produce valid scientific evidence regarding safety and efficacy of the C3 in establishing urinary drainage and allowing the control of micturition when indwelling for up to 7 days in patients. The total study population will initially include 50 subjects with open enrollment of additional subjects.
|
Device: C3 "UMBRELLA CATHETER"
The C3 is an alternative method to facilitate bladder drainage in the study population which are using either a foley catheter or Clean Intermittent Catheter technique to drain the bladder. |
- Catheterization of the bladder from an antegrade direction with the C3 device. [ Time Frame: Measurement of data points are collected sequentially every 7 days up to 28 days. ]The percentage for patients enrolled in the student with the C3 inserted who are able to engage the tubular portion of the device into the bladder neck and urethra from the default position in the bladder with resultant drainage of the bladdder.
- The retreat of the C3 back into the bladder from the engaged position [ Time Frame: Measurement of data points are collected sequentially every 7 days up to 28 days. ]The percentage of enrolled patients who upon completion of bladder drainage with the engaged tubular portion of the C3 in bladder neck and urethral location retreats back into the default position in the bladder.
- Reduction in Catheter Acquired Urinary Tract Infection Rate [ Time Frame: Measurement of data points are collected sequentially every 7 days up to 28 days. ]The reduction in Catheter Acquired Urinary Tract Infection (CAUTI) with the C3 "Umbrella Catheter" as compared to the expected incidence with either a Foley Catheter or Self Intermittent Catheter for bladder drainage.
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.
| Ages Eligible for Study: | 21 Years and older (Adult, Older Adult) |
| Sexes Eligible for Study: | Female |
| Gender Based Eligibility: | Yes |
| Accepts Healthy Volunteers: | Yes |
Inclusion Criteria:
- Patients with Bladder Dysfunction requiring mechanical drainage.
- Patients with actual urinary retention
Exclusion Criteria:
- Inability to undergo bladder catheterization (e.g., urethral stricture or history of urethral stricture)
- Gross hematuria
To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.
Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT03353571
| Contact: GAINES W HAMMOND, MD | 863-680-7300 | GHAMMOND@WATSONCLINIC.COM | |
| Contact: ELAYNE HALL | 863-680-7300 | EHALL@WATSONCLINIC.COM |
| United States, Florida | |
| Watson Clinic Llp | Recruiting |
| Lakeland, Florida, United States, 33805 | |
| Contact: GAINES W HAMMOND, MD 863-680-7300 GHAMMOND@WATSONCLINIC.COM | |
| Contact: ELAYNE HALL 863-680-7300 EHALL@WATSONCLINIC.COM | |
| Responsible Party: | Dr. Gaines W. Hammond Jr. MD FACS, SPONSOR- INVESTIGATOR, Hammond, Gaines W., Jr., M.D. FACS |
| ClinicalTrials.gov Identifier: | NCT03353571 |
| Other Study ID Numbers: |
Study # 17/30/08 |
| First Posted: | November 27, 2017 Key Record Dates |
| Last Update Posted: | November 27, 2017 |
| Last Verified: | November 2017 |
| Individual Participant Data (IPD) Sharing Statement: | |
| Plan to Share IPD: | Yes |
| Plan Description: | LISTED IN STUDY INFORMED CONSENT WITH NAME RECOGNITION WITHHELD |
| Supporting Materials: |
Study Protocol Statistical Analysis Plan (SAP) Informed Consent Form (ICF) Clinical Study Report (CSR) Analytic Code |
| Time Frame: | After completion of the study which is anticipated to be March 2018 for a period of 2 years post completion. |
| Access Criteria: | Access with proper credentials with the patient identifying markers withheld. |
| Studies a U.S. FDA-regulated Drug Product: | No |
| Studies a U.S. FDA-regulated Device Product: | Yes |
| Device Product Not Approved or Cleared by U.S. FDA: | Yes |
| Product Manufactured in and Exported from the U.S.: | No |
|
Urinary Bladder, Neurogenic Urinary Retention Urination Disorders Urologic Diseases |
Neurologic Manifestations Nervous System Diseases Urinary Bladder Diseases |