Optimizing Closed-Loop Control of Type 1 Diabetes Mellitus in Adolescents
|
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details. |
| ClinicalTrials.gov Identifier: NCT01890954 |
|
Recruitment Status :
Completed
First Posted : July 2, 2013
Results First Posted : April 15, 2015
Last Update Posted : June 5, 2017
|
- Study Details
- Tabular View
- Study Results
- Disclaimer
- How to Read a Study Record
| Condition or disease | Intervention/treatment | Phase |
|---|---|---|
| Diabetes Mellitus, Type 1 | Device: Diabetes Assistant (DiAs) | Not Applicable |
| Study Type : | Interventional (Clinical Trial) |
| Actual Enrollment : | 17 participants |
| Allocation: | Randomized |
| Intervention Model: | Crossover Assignment |
| Masking: | None (Open Label) |
| Primary Purpose: | Treatment |
| Official Title: | Optimizing Closed-Loop Control of Type 1 Diabetes Mellitus in Adolescents |
| Study Start Date : | August 2013 |
| Actual Primary Completion Date : | February 2014 |
| Actual Study Completion Date : | February 2014 |
| Arm | Intervention/treatment |
|---|---|
|
Active Comparator: DiAs-closed-loop system
eight hours using Closed Loop Control (DiAs) under both, miss insulin bolus for 30 grams of carbohydrates snack or under bolus for an 80 grams of carbohydrates lunch
|
Device: Diabetes Assistant (DiAs)
Diabetes Assistance (DiAs) is a software residing in a Smartphone that contains the algorithms to regulate and control insulin deliveries (insulin bolus for: Basal rate, meal insulin and correction bolus) with inputs glucose values from a CGM and outputs insulin infusion by an insulin pump
Other Name: Closed-Loop system |
|
No Intervention: Sensor Augmented Pump
8 hours observational under both, missed insulin bolus for 30 gr carbohydrates snack and under bolus for an 80 gr carbohydrates lunch. Sensor augmented pump used the patients own insulin settings (basal rate, meal boluses and correction boluses) and a CGM provided by the study team to be used during admission. No DiAs use during this admisssion
|
- Percent of Time Spent Near Normoglycemia [ Time Frame: 8 hours ]Percentage of time that blood glucose (BG) values (measured with both finger-stick and CGM) were near normoglycemia (70-180 mg/dL).
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.
| Ages Eligible for Study: | 13 Years to 18 Years (Child, Adult) |
| Sexes Eligible for Study: | All |
| Accepts Healthy Volunteers: | No |
Inclusion Criteria:
- ≥13 and ≤18 years old
-
Clinical diagnosis of type 1 diabetes mellitus for at least 2 years as noted by the following:
Criteria for documented hyperglycemia (at least 1 criterion must be met):
- Fasting glucose ≥126 mg/dL - confirmed
- Two-hour Oral Glucose Tolerance Test (OGTT) ≥200 mg/dL - confirmed
- Hemoglobin A1c (HbA1c) ≥6.5% documented by history - confirmed
- Random glucose ≥200 mg/dL with symptoms
- No data at diagnosis is available but the participant has a convincing history of hyperglycemia consistent with diabetes
Criteria for requiring insulin at diagnosis (at least 1 criterion must be met):
- Participant required insulin at diagnosis and continually thereafter
- Participant did not start insulin at diagnosis but upon investigator review likely needed insulin (significant hyperglycemia that did not respond to oral agents) and did require insulin eventually and used continually
- Participant did not start insulin at diagnosis but continued to be hyperglycemic, had positive islet cell antibodies - consistent with Latent Autoimmune Diabetes in Adults (LADA) and did require insulin eventually and used continually
- Use of an insulin pump to treat his/her diabetes for at least 6 months
- Actively using a carbohydrate (CHO) /insulin ratio for insulin bolus adjustments in order to keep blood glucose in a predefined range
- Tanner stage II or greater based on physician exam
- HbA1c between <10.5% as measured with DCA2000 or equivalent device
- Not currently known to be pregnant, breast feeding, or intending to become pregnant (females)
- Demonstration of proper mental status and cognition for the study
- Willingness to avoid consumption of acetaminophen-containing products during the study visits involving DexCom use
- Self-reported behavior of snacking without insulin coverage or under bolus for meals
- Willingness to consume a 30 grams snack without insulin coverage and willingness to bolus 75 % of usual treatment for an 80 grams lunch during both admissions
- Willingness to remove home CGM for admissions if the subject typically wears a CGM
- Medication stability in the preceding two months if taking antihypertensive, thyroid, anti-depressant or lipid lowering medication
- Reported history of missed or inaccurate bolus treatments at meal time
Exclusion Criteria:
- Diabetic ketoacidosis (DKA) within the 6 months prior to enrollment
- In adherence with the One Touch Ultra 2 User Guide, subjects with hematocrit levels below 30% or above 55% will be excluded. Severe hypoglycemia resulting in seizure or loss of consciousness in the 12 months prior to enrollment
- Pregnancy; breast feeding, or intention of becoming pregnant
- Uncontrolled arterial hypertension (based on resting blood pressure > 95 percentile as listed according to age and height percentile in the Harriet Lane Handbook of Pediatrics)
- Conditions which may increase the risk of hypoglycemia such as uncontrolled coronary artery disease during the previous year (e.g. history of myocardial infarction, acute coronary syndrome, therapeutic coronary intervention, coronary bypass or stenting procedure, stable or unstable angina, episode of chest pain of cardiac etiology with documented electrocardiogram (EKG) changes, or positive stress test or catheterization with coronary blockages >50%), congestive heart failure, history of cerebrovascular event, seizure disorder, syncope, adrenal insufficiency, neurologic disease or atrial fibrillation
- History of a systemic or deep tissue infection with methicillin-resistant staph aureus or Candida albicans
- History of arrythmia
- Use of a device that may pose electromagnetic compatibility issues and/or radiofrequency interference with the DexCom CGM (implantable cardioverter-defibrillator, electronic pacemaker, neurostimulator, intrathecal pump, and cochlear implants)
- Anticoagulant therapy other than aspirin
- Oral steroids
- Medical condition requiring use of an acetaminophen-containing medication that cannot be withheld for for 24 hours before CGM insertions until the end of each the study admissions.
- Psychiatric disorders that would interfere with study tasks (e.g. inpatient psychiatric treatment within 6 months prior to enrollment)
- Mental incapacity, unwillingness or language barriers precluding adequate understanding or cooperation
- Known current or recent alcohol or drug abuse
- Medical conditions that would make operating a CGM, the DiAs cell phone, or insulin pump difficult (e.g. blindness, severe arthritis, immobility)
- Any skin condition that prevents sensor or pump placement on the abdomen or arm (e.g. bad sunburn, pre-existing dermatitis, intertrigo, psoriasis, extensive scarring, cellulitis)
- Impaired hepatic function measured as alanine aminotransferase or aspartate aminotransferase ≥ three times the upper reference limit
- Impaired renal function measured as creatinine >1.2 times above the upper limit of normal
- Uncontrolled microvascular (diabetic) complications (other than diabetic non-proliferative retinopathy), such as history of laser coagulation, proliferative diabetic retinopathy, known diabetic nephropathy (other than microalbuminuria with normal creatinine) or neuropathy requiring treatment
- Active gastroparesis requiring current medical therapy
- Uncontrolled thyroid disease
- Known bleeding diathesis or dyscrasia
- Known allergy to medical adhesives, components of the insulin pump insertion set or continuous glucose monitor sensor
- Active enrollment in another clinical trial
- Use of anti-diabetic agents other than continuous subcutaneous insulin infusion (CSII) including long-acting insulin, intermediate-acting insulin, metformin, sulfonylureas, meglitinides, thiazolidinediones, dipeptidyl peptidase 4 (DPP-4) inhibitors, glucagon-like peptide 1 agonists and alpha-glucosidase inhibitors
- Subjects with basal rates less than 0.01 units/hour
RESTRICTIONS ON USE OF OTHER DRUGS OR TREATMENTS
- Use of anti-diabetic agents other than CSII including long-acting insulin, intermediate-acting insulin, metformin, sulfonylureas, meglitinides, thiazolidinediones, DPP-4, inhibitors, glucagon-like peptide 1 agonists, and alpha-glucosidase inhibitors.
- Acetaminophen will be restricted 24 hours before the insertion of not be allowed while the continuous glucose monitor is in use.
- Medications that block symptoms of hypoglycemia, including but not limited to beta blockers.
- Subjects on amylin analogs will be asked to withhold the medication during the outpatient admissions.
To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.
Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT01890954
| United States, Virginia | |
| University of Virginia Center for Diabetes Technology | |
| Charlottesville, Virginia, United States, 22904 | |
| Principal Investigator: | Daniel R. Chernavvsky, MD, CRC | University of Virginia | |
| Principal Investigator: | Mark DeBoer, MD | University of Virginia |
| Responsible Party: | Daniel Chernavvsky, MD, CRC, Co-Principal Investigator, University of Virginia |
| ClinicalTrials.gov Identifier: | NCT01890954 |
| Other Study ID Numbers: |
16890 |
| First Posted: | July 2, 2013 Key Record Dates |
| Results First Posted: | April 15, 2015 |
| Last Update Posted: | June 5, 2017 |
| Last Verified: | May 2017 |
| Individual Participant Data (IPD) Sharing Statement: | |
| Plan to Share IPD: | Yes |
| Plan Description: | We will make de-identofoed individual participant data (IPD) collected in this study available to other researchers at the end of the study. Paper published in Pediatric Diabetes |
|
Type 1 Diabetes Mellitus (T1DM) Closed Loop Control (CLC) Diabetes Assistant (DiAs) Continuous Glucose Monitor (CGM) |
|
Diabetes Mellitus Diabetes Mellitus, Type 1 Glucose Metabolism Disorders Metabolic Diseases |
Endocrine System Diseases Autoimmune Diseases Immune System Diseases |