Visual Function With Contralateral AcrySof® ReSTOR® Aspheric SN6AD1 and SN6AD3
|
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details. |
| ClinicalTrials.gov Identifier: NCT00710905 |
|
Recruitment Status :
Terminated
(Postmarket study terminated as the SN6AD3 is no longer promoted.)
First Posted : July 8, 2008
Results First Posted : November 8, 2011
Last Update Posted : November 24, 2011
|
- Study Details
- Tabular View
- Study Results
- Disclaimer
- How to Read a Study Record
| Condition or disease | Intervention/treatment | Phase |
|---|---|---|
| Cataract | Device: AcrySof ReSTOR Aspheric IOL models SN6AD1 and SN6AD3 | Phase 4 |
| Study Type : | Interventional (Clinical Trial) |
| Actual Enrollment : | 50 participants |
| Allocation: | Non-Randomized |
| Intervention Model: | Single Group Assignment |
| Masking: | None (Open Label) |
| Primary Purpose: | Treatment |
| Official Title: | Visual Function With Contralateral AcrySof® ReSTOR® Aspheric SN6AD1 and SN6AD3 |
| Study Start Date : | October 2009 |
| Actual Primary Completion Date : | September 2010 |
| Actual Study Completion Date : | September 2010 |
| Arm | Intervention/treatment |
|---|---|
|
Experimental: ReSTOR
Contralateral implantation of AcrySof ReSTOR +3 Intraocular Lens (IOL) in one eye, Acrysof ReSTOR +4 IOL in the other eye.
|
Device: AcrySof ReSTOR Aspheric IOL models SN6AD1 and SN6AD3
Contralateral implantation of AcrySof ReSTOR +3 Intraocular Lens (IOL) in one eye, AcrySof ReSTOR +4 IOL in the other eye following cataract removal. |
- Binocular Visual Acuity at Near, Intermediate and Distance [ Time Frame: 6 months after surgery ]Binocular uncorrected and best corrected visual acuity (VA) was tested at 4 meters (m) (distance), 60 centimeters (cm) (intermediate), and near at preferred distance (distance chosen by each subject and recorded in cm; mean and standard deviation calculated) with a standard ETDRS chart for distance and a hand held chart for near. Scores were calculated using logMAR values. LogMAR is the "logarithm of the minimum angle of resolution". A lower logMAR value indicates better VA.
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.
| Ages Eligible for Study: | 21 Years and older (Adult, Older Adult) |
| Sexes Eligible for Study: | All |
| Accepts Healthy Volunteers: | No |
Inclusion Criteria:
- Prospective subjects should be 21 years of age and older, be of any race and gender and meet study entry criteria. Subject must require extraction of cataracts followed by implantation of a posterior chamber intraocular lens (IOL). Subjects must be candidates for bilateral removal of the natural crystalline lens followed by implantation of a multifocal IOL and be willing and able to complete all follow-up visits.
Exclusion Criteria:
- Subjects with pre-existing conditions that could skew the results or are contraindications for the AcrySof® ReSTOR® IOL should be excluded from the study. Please consult the AcrySof® ReSTOR® Aspheric product inserts under "Precautions" for subject groups that should be excluded from this study.
- All subjects must have ≤ 0.75 diopters of astigmatism preoperatively as measured by Keratometry (K) readings. If the surgeon determines that a correction of cylinder is necessary postoperatively, this may be performed after the three month evaluations are completed.
To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.
Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT00710905
| Canada, British Columbia | |
| Dr John Blaylock | |
| Abbotsford, British Columbia, Canada, V2S 5A1 | |
| Canada, Quebec | |
| Dr Dominique Meyer | |
| Quebec City, Quebec, Canada, G1S 1X6 | |
| Principal Investigator: | John Blaylock |
| Responsible Party: | Alcon Research |
| ClinicalTrials.gov Identifier: | NCT00710905 |
| Other Study ID Numbers: |
ALCONsur002.08 |
| First Posted: | July 8, 2008 Key Record Dates |
| Results First Posted: | November 8, 2011 |
| Last Update Posted: | November 24, 2011 |
| Last Verified: | November 2011 |
|
Cataract IOL ReSTOR Aspheric Bilateral cataract |
|
Cataract Lens Diseases Eye Diseases |