Effect of Added Varnum Mouthpiece on Pharyngeal Collapsibility and Sleep Apnea Severity in Mouth Breathers.

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details.
 
ClinicalTrials.gov Identifier: NCT02738255
Recruitment Status : Completed
First Posted : April 14, 2016
Results First Posted : July 3, 2018
Last Update Posted : July 3, 2018
Sponsor:
Information provided by (Responsible Party):
David Andrew Wellman, Brigham and Women's Hospital

Tracking Information
First Submitted Date  ICMJE April 12, 2016
First Posted Date  ICMJE April 14, 2016
Results First Submitted Date  ICMJE March 7, 2018
Results First Posted Date  ICMJE July 3, 2018
Last Update Posted Date July 3, 2018
Actual Study Start Date  ICMJE June 2, 2016
Actual Primary Completion Date June 15, 2017   (Final data collection date for primary outcome measure)
Current Primary Outcome Measures  ICMJE
 (submitted: June 1, 2018)
Sleep Apnea Severity as Measured by Apnea-hypopnea Index (AHI) [ Time Frame: Two nights: night with Varnum mouthpiece and night without Varnum mouthpiece ]
The number of respiratory events (apneas and hypopneas) per hour of sleep. This was measured on two nights in random order (night with Varnum mouthpiece and night without Varnum mouthpiece). The median AHI on the night with Varnum mouthpiece was then compared with median AHI on the night without Varnum mouthpiece.
Original Primary Outcome Measures  ICMJE
 (submitted: April 12, 2016)
Decrease in sleep apnea severity as measured by apnea-hypopnea index (AHI) [ Time Frame: Acutely (1 night) ]
Change History
Current Secondary Outcome Measures  ICMJE
 (submitted: June 1, 2018)
  • Pharyngeal Collapsibility as Measured by Median Peak Inspiratory Flow During Sleep [ Time Frame: Two nights: night with Varnum mouthpiece and night without Varnum mouthpiece ]
    The median peak flow during sleep was measured and compared on both nights (night with Varnum mouthpiece and night without Varnum mouthpiece). The median peak flow is a surrogate measure of upper airway collapsibility.
  • Snoring Index in Simple Snorers [ Time Frame: Two nights: night with Varnum mouthpiece and night without Varnum mouthpiece ]
    Snoring index is the number of breaths with snoring per hour of sleep. This was measured in both nights (night with Varnum mouthpiece and night without Varnum mouthpiece) only in simple snorers with AHI<10. The median of snoring index was compared between night with Varnum mouthpiece and night without Varnum mouthpiece.
Original Secondary Outcome Measures  ICMJE
 (submitted: April 12, 2016)
Decrease in pharyngeal collapsibility as measured by median peak inspiratory flow during sleep [ Time Frame: Acutely (1 night) ]
Current Other Pre-specified Outcome Measures Not Provided
Original Other Pre-specified Outcome Measures Not Provided
 
Descriptive Information
Brief Title  ICMJE Effect of Added Varnum Mouthpiece on Pharyngeal Collapsibility and Sleep Apnea Severity in Mouth Breathers.
Official Title  ICMJE Effect of Added Varnum Mouthpiece on Pharyngeal Collapsibility and Sleep Apnea Severity in Mouth Breathers.
Brief Summary Test the effect of added a single-use Varnum mouthpiece on pharyngeal collapsibility and obstructive sleep apnea (OSA) severity in patients who identify themselves as mouth breathers. Research indicates that nasal breathing not only may improve sleep apnea but it also increases circulation, blood oxygen, and carbon dioxide levels, slows the breathing rate, and improves overall lung volumes. Thus, the investigators will test whether a single-use Varnum mouthpiece can improve pharyngeal collapsibility and OSA severity in mouth breathers.
Detailed Description

Obstructive sleep apnea (OSA) is a common disorder that remains under-treated due few therapeutic options beyond continuous positive airway pressure (CPAP). In patients with OSA, upper airway obstruction is caused by collapse of pharyngeal structures during sleep. It is known that mouth breathing increases upper-airway collapsibility during sleep and may contribute to the occurrence of sleep disordered breathing. In addition, it was shown that patients with a high percentage of mouth breathing during sleep were less adherent to CPAP therapy. Therefore, one potential solution to these problems is to use Varnum's mouthpiece to prevent mouth breathing during sleep.

The overall objective of the current study is to improve upper airway collapsibility and sleep apnea in OSA patients who have a high percentage of mouth breathing during sleep. The investigators' central hypothesis is that preventing the lips from parting with the Varnum device will reduce oral breathing and thereby OSA severity in mouth breathers. The investigators chose this hypothesis because "taping the mouth closed" with a simple device such as the Varnum mouthpiece is the most straightforward approach to dealing with this common problem. With this research, it could become possible to overcome one of the major problems contributing to sleep apnea - mouth breathing.

Therefore, the investigators aim to test the effect of the Varnum mouthpiece on pharyngeal collapsibility and OSA severity in patients who identify themselves as mouth breathers. The investigators' working hypothesis is that the device will keep the lips from separating and thereby prevent oral breathing. In doing so, it may help keep the airway more patent (by promoting nasal instead of oral breathing) in self-described mouth breathers and thus reduce OSA severity. On the contrary, the investigators believe patients who do not identify themselves as mouth breathers might not benefit significantly from the Varnum device.

The expected outcome of this study is validation of new device for improving sleep apnea in a large subgroup of easily identifiable OSA patients, namely self-described mouth breathers. Such a device could advance the field by providing more effective alternative treatments.

Study Type  ICMJE Interventional
Study Phase  ICMJE Not Applicable
Study Design  ICMJE Allocation: Randomized
Intervention Model: Crossover Assignment
Masking: Single (Outcomes Assessor)
Primary Purpose: Treatment
Condition  ICMJE Obstructive Sleep Apnea
Intervention  ICMJE Device: Varnum mouthpiece
Study Arms  ICMJE
  • Active Comparator: Polysomnogram with Varnum Mouthpiece
    Varnum mouthpiece, similar to a mouth tape with central opening
    Intervention: Device: Varnum mouthpiece
  • No Intervention: Regular Polysomnogram
    Overnight sleep study with no mouthpiece
Publications * Not Provided

*   Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline.
 
Recruitment Information
Recruitment Status  ICMJE Completed
Actual Enrollment  ICMJE
 (submitted: June 1, 2018)
26
Original Estimated Enrollment  ICMJE
 (submitted: April 12, 2016)
30
Actual Study Completion Date  ICMJE June 15, 2017
Actual Primary Completion Date June 15, 2017   (Final data collection date for primary outcome measure)
Eligibility Criteria  ICMJE

Inclusion Criteria:

  • Presence of obstructive sleep apnea (AHI>10 events/hr)

Exclusion Criteria:

  • Serious co-morbidities including lung disease, heart disease, renal disease
  • Medications affecting respiration or sleep

Mouth breather subgroup inclusion criteria: self-described mouth breathing habit during sleep.

non-mouth breathing subgroup inclusion criteria: absence of self-described mouth breathing during sleep

Sex/Gender  ICMJE
Sexes Eligible for Study: All
Ages  ICMJE 21 Years to 70 Years   (Adult, Older Adult)
Accepts Healthy Volunteers  ICMJE No
Contacts  ICMJE Contact information is only displayed when the study is recruiting subjects
Listed Location Countries  ICMJE United States
Removed Location Countries  
 
Administrative Information
NCT Number  ICMJE NCT02738255
Other Study ID Numbers  ICMJE 2012P000957F
Has Data Monitoring Committee No
U.S. FDA-regulated Product Not Provided
IPD Sharing Statement  ICMJE
Plan to Share IPD: Yes
Responsible Party David Andrew Wellman, Brigham and Women's Hospital
Study Sponsor  ICMJE David Andrew Wellman
Collaborators  ICMJE Not Provided
Investigators  ICMJE Not Provided
PRS Account Brigham and Women's Hospital
Verification Date June 2018

ICMJE     Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP