CARTO® 3 System and Real Time Intracardiac Ultrasound (IUAF)

This study has been completed.
Sponsor:
ClinicalTrials.gov Identifier:
NCT01716663
First Posted: October 30, 2012
Last Update Posted: December 1, 2014
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details.
Information provided by (Responsible Party):
Biosense Webster, Inc.
October 19, 2012
October 30, 2012
November 24, 2014
December 1, 2014
December 1, 2014
October 2012
September 2013   (Final data collection date for primary outcome measure)
Total Fluoroscopy Time [ Time Frame: Day 0 ]
The fluoroscopy time will be measured for each phase (access, mapping, ablation, and validation) of the procedure and summed to derive the total.
Fluoroscopy Time [ Time Frame: Day 0 ]
The fluoroscopy time will be measured for each phase (access, mapping, ablation, and validation) of the procedure.
Complete list of historical versions of study NCT01716663 on ClinicalTrials.gov Archive Site
  • Total Procedure Time [ Time Frame: Day 0 ]
    The procedure time will be measured for each phase (access, mapping, ablation, and validation) of the procedure and summed to derive the total.
  • Acute Procedural Success [ Time Frame: Day 0 ]
    Acute success will be defined as confirmation of pulmonary vein isolation by entrance block, exit block, and/or periostial block of all targeted pulmonary veins.
  • Mean Number of Radiofrequency (RF) Applications [ Time Frame: Day 0 ]
    RF application is defined as the number of times RF energy is delivered during the procedure.
  • Total Radiofrequency (RF) Time [ Time Frame: Day 0 ]
    Total RF time is defined as the total time RF is delivered during the procedure.
  • Procedure Time [ Time Frame: Day 0 ]
    The procedure time will be measured for each phase (access, mapping, ablation, and validation) of the procedure.
  • Acute Success [ Time Frame: Day 0 ]
    Acute success will be measured via confirmation of pulmonary vein isolation method.
  • Safety [ Time Frame: Within 7 days of the procedure ]
    Procedural complications, electrocardiogram abnormalities and adverse events.
  • Number of Radiofrequency (RF) Applications [ Time Frame: Day 0 ]
    RF application will be measured by number of times delivered during the procedure.
  • Total Radiofrequency (RF) Time [ Time Frame: Day 0 ]
    Total RF time will be measured for the total time RF is delivered during the procedure.
Not Provided
Not Provided
 
CARTO® 3 System and Real Time Intracardiac Ultrasound
CARTO® 3 System and Real Time Intracardiac Ultrasound for Ablation of Drug Refractory Recurrent Symptomatic Paroxysmal AF: Acute Procedural Outcomes Study
This is a prospective, multicenter, non-randomized observational study of subjects 18 years and older undergoing RF ablation with drug refractory recurrent symptomatic paroxysmal Atrial Fibrillation (AF).
This study is purposed to measure "real world" acute procedural outcomes (procedural efficiency and acute safety) associated with use of the CARTO® 3 System and real time intracardiac ultrasound in a clinical setting in subjects with drug refractory recurrent symptomatic paroxysmal AF.
Observational
Time Perspective: Prospective
Not Provided
Not Provided
Non-Probability Sample
Subjects 18 years and older with drug refractory recurrent symptomatic paroxysmal AF
  • Atrial Fibrillation
  • Paroxysmal AF
Device: Catheter Ablation
NAVISTAR® THERMOCOOL® SF Catheter with the CARTO® 3 System and the SOUNDSTAR® Ultrasound Catheter (with the CARTOSOUND® Software Module)
Other Name: CARTO® 3 System and Real Time Intracardiac Ultrasound
Experimental: Catheter Ablation
These patients have drug refractory recurrent symptomatic paroxysmal AF, are 18 years and older, and are able and willing to provide written informed consent to participate in the study and comply with study requirements.
Intervention: Device: Catheter Ablation
Not Provided

*   Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline.
 
Completed
234
September 2013
September 2013   (Final data collection date for primary outcome measure)

Inclusion Criteria:

  • Drug refractory, recurrent symptomatic paroxysmal AF
  • Age 18 years or older
  • Patients able and willing to provide written informed consent to participate in the study and comply with study requirements

Exclusion Criteria:

  • Atrial fibrillation secondary to electrolyte imbalance, thyroid disease, or reversible or non-cardiac cause
  • Previous ablation for atrial fibrillation
  • AF episodes that last longer than 30 days
  • Uncontrolled heart failure, or NYHA Class III or IV heart failure
  • Documented intra-atrial thrombus or other abnormality on pre-ablation imaging
  • Contraindication to anticoagulation
  • Stroke, cardiac surgery, unstable angina, myocardial infarction or percutaneous coronary intervention within the past 3 months
  • Awaiting cardiac transplantation
  • Heart disease for which corrective surgery is anticipated within 6 months
  • Enrollment in other investigational drug or device study
  • Subjects unwilling to comply with protocol or follow-up requirements
  • Patients who are pregnant
Sexes Eligible for Study: All
18 Years and older   (Adult, Senior)
Yes
Contact information is only displayed when the study is recruiting subjects
United States
 
 
NCT01716663
IUAF
No
Not Provided
Not Provided
Biosense Webster, Inc.
Biosense Webster, Inc.
Not Provided
Principal Investigator: Usman Siddiqui, MD Osceola Regional Medical Center
Principal Investigator: Mathew Hutchinson, MD University of Pennsylvania
Principal Investigator: Andy Tran, MD Scottsdale Healthcare Research
Principal Investigator: Saumil Oza, MD East Coast Institute for Research LLC, St. Vincent's Ambulatory Care, Inc.
Principal Investigator: Robert Fishel, MD JFK Medical Center
Principal Investigator: Vijendra Swarup, MD AZ Heart Rhythm Research Center
Principal Investigator: Mohit Rastogi, MD Washington Adventist Hospital CCVR
Principal Investigator: Brett Gidney, MD Santa Barbara Cottage Hospital
Principal Investigator: John Scherschel, MD University of Nebraska
Principal Investigator: Dilip Mathew, MD Pepin Heart Hospital
Principal Investigator: William Sauer, MD University of Colorado, Denver
Principal Investigator: Marcie Berger, MD Medical College of Wisconsin
Principal Investigator: Khawaja Baig, MD Kettering Medical Center
Principal Investigator: Farhat Khairallah, MD Tallahassee Research Institute
Principal Investigator: David Fitzgerald, MD Scott & White Memorial Hospital
Principal Investigator: Gopi Dandamudi, MD Geisinger Heart Institute
Principal Investigator: Ahmad Abdul-Karim, MD Provena St. Joseph Medical Center
Principal Investigator: Douglas Esberg, MD Main Line Health
Principal Investigator: Scott Burke, MD St. Mary Medical Center
Principal Investigator: Gregory Jones, MD Wellmont CVA Heart Institute
Principal Investigator: Tapan Rami, MD The Methodist Hospital Research Institute
Principal Investigator: Salem Sayar, MD Northeast Georgia Heart Center, PC
Principal Investigator: Gunjan Shukla, MD Hackensack University Medical Center
Principal Investigator: Philip Gentlesk, MD Sentara Norfolk General Hospital
Principal Investigator: Asim Yunus, MD Michigan CardioVascular Institute
Principal Investigator: Scott Reich, MD Northeast Baptist Hospital
Biosense Webster, Inc.
November 2014