Clinical Study of Aneurysm Exclusion (EndoMed)
![]() |
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details. |
ClinicalTrials.gov Identifier: NCT00549016 |
Recruitment Status : Unknown
Verified May 2009 by Arizona Heart Institute.
Recruitment status was: Recruiting
First Posted : October 25, 2007
Last Update Posted : May 15, 2009
|
Tracking Information | ||||
---|---|---|---|---|
First Submitted Date ICMJE | October 24, 2007 | |||
First Posted Date ICMJE | October 25, 2007 | |||
Last Update Posted Date | May 15, 2009 | |||
Study Start Date ICMJE | November 2002 | |||
Estimated Primary Completion Date | November 2012 (Final data collection date for primary outcome measure) | |||
Current Primary Outcome Measures ICMJE |
Technical success in the deployment and placement of the endoluminal graft to the aneurysmal site. [ Time Frame: 1 month ] | |||
Original Primary Outcome Measures ICMJE | Same as current | |||
Change History | ||||
Current Secondary Outcome Measures ICMJE |
Acute success when the endoluminal graft excludes the aneurysm and maintain patency without endoleaks, migration or rupture. [ Time Frame: 1 month ] | |||
Original Secondary Outcome Measures ICMJE | Same as current | |||
Current Other Pre-specified Outcome Measures | Not Provided | |||
Original Other Pre-specified Outcome Measures | Not Provided | |||
Descriptive Information | ||||
Brief Title ICMJE | Clinical Study of Aneurysm Exclusion | |||
Official Title ICMJE | Clinical Study of Aneurysm Exclusion Using PTFE Encapsulation of Nitinol Stents | |||
Brief Summary | The ultimate purpose is to explore the potential techniques to exclude aneurysms and provide an alternative conduit for arterial flow. The single center sponsorship is intended to provide the investigators the potential to incorporate improvements in existing technology during the course of the study thereby ultimately enhancing the potential for superior medical care of patients suffering from these disease states. The sponsor/investigator recognizes and accepts responsibility to notify and receive approval from the agency when device modifications are made that may affect patient safety. | |||
Detailed Description | The Arizona Heart Institute is respectfully submitting this protocol for a feasibility study utilizing the endoluminal grafts constructed of PTFE encapsulated nitinol stents. The study is intended to evaluate the use of this unique device in the treatment of aortic aneurysmal disease. The stent graft is made by laminating a PTFE "jacket" around nitinol stents which act as structural and fixation supports. Both materials have an extensive history of use in various types of implanted devices. CT scans and angiography or 3D computer imaging, and possibly IVUS imaging will be used to choose the sites for placement of the devices and to assure precise deployment. In comparison to the conventional surgical approach, endoluminal stent-graft techniques for repair of abdominal aortic aneurysms (AAAs) offer the advantages of a minimally invasive procedure with lower morbidity and perhaps cost reduction. The Arizona Heart Institute has a long history in the area of endoluminal grafting for treatment of aneurysms and occlusive disease. Endoluminal sleeves principally using ePTFE and both stainless steel and nitinol stent structures have been studied using commercially available materials customized for particular pathologic situations. As the technology advances however, sophisticated engineering beyond the capabilities of our institution was required. The proposed project originates because of the potential to escalate the combination of ePTFE and stents to a higher level of performance in aneurysm exclusion procedures. Current data reflect several deficiencies in approved exclusion devices. Migration, types I, II and III endoleaks and continual aneurysm expansion are clear predictors for potential ruptures. Increased complications associated with the initial peri-procedural deployment as devices are released on a broader scale have been observed. In order to address these problems, the Arizona Heart Institute has engaged EndoMed engineering to design the endoluminal graft to repair abdominal aortic aneurysms. We believe this will result in a positive step forward in the technology to exclude aneurysmal disease less invasively. The endoluminal stent-graft is composed of multiple nitinol stents which are encapsulated in expanded Polytetrafluoroethylene (ePTFE). The stents are composed of a Z-shaped, performed nitinol wire, which is crimped together with a stainless steel sleeve to form the circular frame of the graft. This frame is then encapsulated between two thin sheets of laminated PTFE. The proximal end of the endoluminal stent-graft is made in two configurations. One is a completely encapsulated graft where the PTFE covers the entire device. The other has an open stent segment (bare wire configuration) that allows the open stent region of the graft to be placed across the orifice of the renal, mesenteric, or internal iliac arteries without obstructing antegrade blood flow. The device will be available in a straight tube, aortomonoiliac or bifurcated design. Once the endoluminal stent graft is built, a 4 French guidewire dilator is placed through the center of the graft and the assembly is compressed into a high density polyethylene (HDPE) cartridge for ease of intraluminal delivery. The endoluminal stent-graft is then placed in two Tyvek pouches and sterilized using Hydrogen Peroxide. Subjects will undergo an evaluation of the PTFE encapsulation of Nitinol stents to provide data on the device's feasibility for therapeutic clinical use. Follow-up will be completed at 1, 6, 12, 24, 36, 48, and 60 months. Subject evaluation at 1 month will include a Complete History and Physical, Bilateral ABIs, Abdominal Duplex Ultrasound, and a KUB X-ray (4 views). Subject evaluation at 6 months will also include a Complete History and Physical, Bilateral ABIs, Abdominal Duplex Ultrasound, KUB X-ray (4 views), and based on the duplex ultrasound an Abdominal CT scan with and without IV contrast 2.5 mm and Labs (BUN/Creatinine). Subject evaluation at 12, 24, 36, 48, and 60 months will include a Complete History and Physical, Bilateral ABIs, Abdominal CT scan with and without IV contrast 2.5 mm, Abdominal Duplex Ultrasound, KUB X-ray (4 views), and Labs (BUN/Creatinine). |
|||
Study Type ICMJE | Interventional | |||
Study Phase ICMJE | Not Applicable | |||
Study Design ICMJE | Allocation: N/A Intervention Model: Single Group Assignment Masking: None (Open Label) Primary Purpose: Treatment |
|||
Condition ICMJE | Aneurysm | |||
Intervention ICMJE | Device: PTPE Encapsulation of Nitinol Stents
Both common femoral arteries (CFAs) are surgically exposed to allow bilateral access of diagnostic and therapeutic devices. The endoluminal stent graft is then deployed in accordance with the Instructions for Use.
|
|||
Study Arms ICMJE | Experimental: 1
Intervention: Device: PTPE Encapsulation of Nitinol Stents
|
|||
Publications * | Not Provided | |||
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
||||
Recruitment Information | ||||
Recruitment Status ICMJE | Unknown status | |||
Estimated Enrollment ICMJE |
150 | |||
Original Estimated Enrollment ICMJE | Same as current | |||
Estimated Study Completion Date ICMJE | November 2012 | |||
Estimated Primary Completion Date | November 2012 (Final data collection date for primary outcome measure) | |||
Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
|||
Sex/Gender ICMJE |
|
|||
Ages ICMJE | 18 Years and older (Adult, Older Adult) | |||
Accepts Healthy Volunteers ICMJE | No | |||
Contacts ICMJE | Contact information is only displayed when the study is recruiting subjects | |||
Listed Location Countries ICMJE | United States | |||
Removed Location Countries | ||||
Administrative Information | ||||
NCT Number ICMJE | NCT00549016 | |||
Other Study ID Numbers ICMJE | G020035 | |||
Has Data Monitoring Committee | No | |||
U.S. FDA-regulated Product | Not Provided | |||
IPD Sharing Statement ICMJE | Not Provided | |||
Current Responsible Party | Edward B. Diethrich, MD, Arizona Heart Institute | |||
Original Responsible Party | Not Provided | |||
Current Study Sponsor ICMJE | Arizona Heart Institute | |||
Original Study Sponsor ICMJE | Same as current | |||
Collaborators ICMJE | Not Provided | |||
Investigators ICMJE |
|
|||
PRS Account | Arizona Heart Institute | |||
Verification Date | May 2009 | |||
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |