Noninvasive Dual-mode Stimulation Therapy for Neurorehabilitation in Post-stroke Cognitive Impairment

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details.
 
ClinicalTrials.gov Identifier: NCT03647319
Recruitment Status : Completed
First Posted : August 27, 2018
Last Update Posted : September 20, 2019
Sponsor:
Information provided by (Responsible Party):
Samsung Medical Center

Brief Summary:

Repetitive transcranial magnetic stimulation (rTMS) or transcranial direct current stimulation (tDCS) has been used for the modulation of post-stroke cognitive impairment patients' cognitive function by altering the cortical excitability.

Recently, more challenging approaches, such as stimulation of two or more sites or use of dual modality have been studied in stroke patients. In this study, simultaneous stimulation using both facilitatory rTMS (10Hz) and anodal or cathodal tDCS (dual-mode stimulation) over bilateral dorsolateral prefrontal cortices (DLPFCs) was investigated to compare its modulatory effects with single facilitatory rTMS stimulation in post-stroke cognitive impairment patients.


Condition or disease Intervention/treatment Phase
Post-stroke Cognitive Impairment Device: High-frequency rTMS on left DLPFC+anodal tDCS on right DLPFC Device: High-frequency rTMS on left DLPFC+cathodal tDCS on right DLPFC Device: High-frequency rTMS on left DLPFC+sham tDCS on right DLPFC Not Applicable

Layout table for study information
Study Type : Interventional  (Clinical Trial)
Actual Enrollment : 29 participants
Allocation: Randomized
Intervention Model: Parallel Assignment
Masking: Single (Participant)
Primary Purpose: Treatment
Official Title: Investigation for Individualized Noninvasive Neuromodulation in Neurorehabilitation of Brain Disease: Longitudinal Study
Actual Study Start Date : April 11, 2013
Actual Primary Completion Date : November 10, 2016
Actual Study Completion Date : November 10, 2016

Arm Intervention/treatment
Experimental: Anodal Dual-mode stimulation

10Hz of rTMS was applied over the left DLPFC for 10 minutes with simultaneous application of anodal tDCS on the right DLPFC.

Each participant's 2-back verbal/nonverbal working memory task and variety cognitive function test are assessed and their resting-state fMRI data at three times: prior to stimulation (pre-stimulation), immediately after stimulation (post-stimulation) and 2 months after stimulation (f/u) are acquired.

Device: High-frequency rTMS on left DLPFC+anodal tDCS on right DLPFC
10Hz rTMS over the left DLPFC and anodal tDCS over the right DLPFC are simultaneously stimulated.

Experimental: Cathodal Dual-mode stimulation

10Hz of rTMS was applied over the left DLPFC for 10 minutes with simultaneous application of cathodal tDCS on the right DLPFC.

Each participant's 2-back verbal/nonverbal working memory task and variety cognitive function test are assessed and their resting-state fMRI data at three times: prior to stimulation (pre-stimulation), immediately after stimulation (post-stimulation) and 2 months after stimulation (f/u) are acquired.

Device: High-frequency rTMS on left DLPFC+cathodal tDCS on right DLPFC
10Hz rTMS over the left DLPFC and cathodal tDCS over the right DLPFC are simultaneously stimulated.

Active Comparator: Single sham stimulation

10Hz of rTMS was applied over the left DLPFC for 10 minutes with simultaneous application of tDCS with sham mode (no stimulation) on the right DLPFC.

Each participant's 2-back verbal/nonverbal working memory task and variety cognitive function test are assessed and their resting-state fMRI data at three times: prior to stimulation (pre-stimulation), immediately after stimulation (post-stimulation) and 2 months after stimulation (f/u) are acquired.

Device: High-frequency rTMS on left DLPFC+sham tDCS on right DLPFC
10Hz rTMS over the left DLPFC and sham tDCS (no stimulation) over the right DLPFC are simultaneously stimulated.




Primary Outcome Measures :
  1. Accuracy of 2-back verbal working memory task [ Time Frame: Change from Pre-intervention at 2 months ]
    Accuracy (percentile) of 2-back verbal working memory task



Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Layout table for eligibility information
Ages Eligible for Study:   Child, Adult, Older Adult
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • First-ever stroke patients
  • Subacute stage (less than 4 weeks)
  • Who can perform the 2-back verbal and non-verbal working memory task

Exclusion Criteria:

  • K-MMSE score under 9
  • Major active neurological disease or psychiatric disease
  • A history of seizure
  • Metallic implants in their brain

Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT03647319


Locations
Layout table for location information
Korea, Republic of
Samsung Medical Center
Seoul, Korea, Republic of
Sponsors and Collaborators
Samsung Medical Center

Layout table for additonal information
Responsible Party: Samsung Medical Center
ClinicalTrials.gov Identifier: NCT03647319     History of Changes
Other Study ID Numbers: 2013-06-002-016
First Posted: August 27, 2018    Key Record Dates
Last Update Posted: September 20, 2019
Last Verified: September 2019

Layout table for additional information
Studies a U.S. FDA-regulated Drug Product: No
Studies a U.S. FDA-regulated Device Product: No
Keywords provided by Samsung Medical Center:
Noninvasive Brain Stimulation
Repetitive Transcranial Magnetic Stimulation
Transcranial Direct Current Stimulation
Additional relevant MeSH terms:
Layout table for MeSH terms
Stroke
Cognitive Dysfunction
Cerebrovascular Disorders
Brain Diseases
Central Nervous System Diseases
Nervous System Diseases
Vascular Diseases
Cardiovascular Diseases
Cognition Disorders
Neurocognitive Disorders
Mental Disorders