The Vascutek Custom Fenestrated Anaconda Post-Market Surveillance Study

This study has been terminated.
Sponsor:
ClinicalTrials.gov Identifier:
NCT01826344
First Posted: April 8, 2013
Last Update Posted: December 9, 2015
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Read our disclaimer for details.
Information provided by (Responsible Party):
Vascutek Ltd.
  Purpose
This is a multicentre, prospective, observational post-market registry (follow-up 1 month, 1 year, 2 years, 3 years, 4 years and 5 years) to monitor the post-market clinical safety and effectiveness of the Vascutek AnacondaTM Custom Fenestrated Stent Graft in patients with a short infrarenal neck of <15mm or juxta-renal abdominal aortic aneurysms who, in the opinion of the treating physician, are anatomically suitable for the AnacondaTM Custom Fenestrated Stent Graft and for whom a customised medical device is required.

Condition
Abdominal Aortic Aneurysms (AAA)

Study Type: Observational [Patient Registry]
Study Design: Observational Model: Cohort
Time Perspective: Prospective
Target Follow-Up Duration: 5 Years

Resource links provided by NLM:


Further study details as provided by Vascutek Ltd.:

Primary Outcome Measures:
  • To monitor the the post-market clinical safety and effectiveness of the Vascutek AnacondaTM Custom Fenestrated Stent Graft [ Time Frame: For 5 years post-implant ]
    To monitor the post-market clinical safety and effectiveness of the Vascutek AnacondaTM Custom Fenestrated Stent Graft in patients with a short infrarenal neck of <15mm or juxta-renal abdominal aortic aneurysms who, in the opinion of the treating physician, are anatomically suitable for the AnacondaTM Custom Fenestrated Stent Graft and for whom a customised medical device is required.


Enrollment: 628
Study Start Date: June 2010
Study Completion Date: December 2015
Primary Completion Date: December 2015 (Final data collection date for primary outcome measure)
Detailed Description:

AnacondaTM Custom Fenestrated Devices (CFD) are designed for the endovascular repair of abdominal aortic aneurysms (AAA) for cases where the aneurysm extends superiorly very close to or involving the renal arteries, leaving insufficient neck length for infrarenal device sealing. The non-CE marked devices are custom designed based on CT scan data of the patient's aorta and regulated in accordance with the Medical Device Directive (93/42/EEC) and associated country specific regulations as applicable.

The proximal end of the AnacondaTM fenestrated body device is positioned suprarenally, where it seals and fixates in the vessel by means of rings comprised of multiple turns of fine nitinol wire, attached to the fabric with polyester sutures, creating a self-expanding stent which provides a conformable seal with the vessel wall and assists in anchoring of the device. Nitinol hooks provide secure fixation within the suprarenal aorta. The saddle shape of the rings allows the superior mesenteric artery (SMA) or celiac artery to be accommodated in the valley of the top ring saddle in some cases.

The objective of the registry is to provide long term (5 year) safety and effectiveness data of all patients who consent to their data to be used in the registry. This data aims to demonstrate that the Vascutek AnacondaTM Custom Fenestrated Stent Graft is safe and effective in patients with a short infrarenal neck of <15mm or juxta-renal abdominal aortic aneurysms who, in the opinion of the treating physician, are anatomically suitable for the AnacondaTM Custom Fenestrated Stent Graft.

  Eligibility

Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Ages Eligible for Study:   18 Years and older   (Adult, Senior)
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   No
Sampling Method:   Non-Probability Sample
Study Population
Patients with a short infrarenal neck of <15mm or juxta-renal abdominal aortic aneurysms who, in the opinion of the treating physician, are anatomically suitable for the AnacondaTM Custom Fenestrated Stent Graft and for whom a customised medical device is required.
Criteria

Inclusion Criteria:

A patient with juxta renal abdominal aortic aneurysms (AAA) who, in the opinion of the treating physician, is anatomically suitable for the Anaconda Fenestrated Graft and for whom a customised medical device is required.

Exclusion Criteria:

  1. Ruptured or symptomatic aneurysm
  2. Clinically significant concomitant medical disease or infection
  3. Connective Tissue Disease (e.g. Marfan's Syndrome)
  4. Known allergy to nitinol, polyester or contrast medium
  5. Excessive tortuosity of access vessels (femoral or iliac arteries)
  6. Landing zone of less than 10mm in the visceral segment of the aorta
  7. Inability to comply to follow up protocol
  8. Access vessels less than 6mm in diameter
  9. Diseased or excessively tortuous access to target vessels
  10. Target vessels of less than 5mm in calibre
  11. Excessive calcification or thrombus at the intended landing zone which could affect sealing
  Contacts and Locations
Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT01826344


  Show 71 Study Locations
Sponsors and Collaborators
Vascutek Ltd.
  More Information

Responsible Party: Vascutek Ltd.
ClinicalTrials.gov Identifier: NCT01826344     History of Changes
Other Study ID Numbers: CFD001
First Submitted: April 3, 2013
First Posted: April 8, 2013
Last Update Posted: December 9, 2015
Last Verified: December 2015

Additional relevant MeSH terms:
Aneurysm
Aortic Aneurysm
Aortic Aneurysm, Abdominal
Vascular Diseases
Cardiovascular Diseases
Aortic Diseases