Mesenteric Vessel Sealing by Three Instruments
- Full Text View
- Tabular View
- No Study Results Posted
- Disclaimer
- How to Read a Study Record
Purpose
Ultrasonic cutting-coagulation devices (UCCD) are surgical instruments which use ultrasonic energy to cut through and coagulate tissue. An Ethicon version (trademarked "Harmonic Scalpel" and "Ultracision") is used in a variety of surgical procedures. Its surgical performance has been directly compared with that of electrically powered diathermy instruments in animal and clinical trials. LOTUS is a company based in Ashburton, Devon, which has developed a UCCD that works in a slightly different way to the Harmonic Scalpel. There are also bipolar feedback diathermy instruments which use electrical energy to seal blood vessels, such as LigaSure. The aim of this project is to obtain data to design a fully powered trial to answer the research question: do LOTUS and Ethicon UCCDs and LigaSure bipolar device reliably seal and divide blood vessels? The investigators will also be examining the degree of collateral tissue damage caused by each instrument.
Hypotheses
- LOTUS UCCD, Ethicon Harmonic Scalpel and LigaSure are equivalent at sealing and dividing mesenteric blood vessels.
- LOTUS UCCD, Ethicon Harmonic Scalpel and LigaSure cause equal amount of collateral damage when sealing and dividing blood vessels.
| Condition | Intervention |
|---|---|
|
Surgery |
Device: LOTUS Device: Ethicon Harmonic Scalpel Device: LigaSure bipolar vessel sealing device |
| Study Type: | Interventional |
| Study Design: | Allocation: Randomized Endpoint Classification: Safety/Efficacy Study Intervention Model: Single Group Assignment Masking: Single Blind (Outcomes Assessor) Primary Purpose: Basic Science |
| Official Title: | A Pilot Study to Compare Collateral Damage and Vessel Sealing Ability of LOTUS Ultrasonic Shears, Ethicon Harmonic Scalpel™ and LigaSure™ on Human Mesenteric Blood Vessels |
- Bursting pressure of sealed vessel [ Time Frame: 1 day ] [ Designated as safety issue: No ]Designated instrument is used to seal and divide a blood vessel which has been dissected from large bowel mesentery. The pressure at which the seal leaks is measured using a pressure transducer, this is known as the "bursting pressure"
- Success/failure to seal vessel [ Time Frame: 1 day ] [ Designated as safety issue: No ]Instrument is used to seal and divide a blood vessel, this outcome is to see whether the seal is complete
- Depth of collateral damage [ Time Frame: After histological fixation is complete; within one week ] [ Designated as safety issue: No ]Energy-based surgical instruments cause a certain amount of thermal damage to the surrounding tissue, to compare the 3 instruments this depth of damage will be measured histologically
| Enrollment: | 18 |
| Study Start Date: | April 2008 |
| Study Completion Date: | June 2008 |
| Primary Completion Date: | June 2008 (Final data collection date for primary outcome measure) |
| Arms | Assigned Interventions |
|---|---|
|
Experimental: LOTUS
LOTUS ultrasonic instrument
|
Device: LOTUS
Device used to seal blood vessel
|
|
Experimental: Ethicon Harmonic Scalpel
Ultrasonic instrument
|
Device: Ethicon Harmonic Scalpel |
|
Experimental: LigaSure
Bipolar feedback vessel sealing device
|
Device: LigaSure bipolar vessel sealing device |
Eligibility| Ages Eligible for Study: | 18 Years and older |
| Genders Eligible for Study: | Both |
| Accepts Healthy Volunteers: | Yes |
Inclusion Criteria:
- Patient undergoing laparoscopic or open colorectal resection
Exclusion Criteria:
- Pregnant or lactating women
- Patients under eighteen years of age
- History of coagulation abnormality
- Inability to understand the nature of the study
Contacts and Locations
More Information
No publications provided by Plymouth Hospitals NHS Trust
Additional publications automatically indexed to this study by ClinicalTrials.gov Identifier (NCT Number):
| Responsible Party: | Plymouth Hospitals NHS Trust |
| ClinicalTrials.gov Identifier: | NCT01121614 History of Changes |
| Other Study ID Numbers: | 06/Q2103/139 |
| Study First Received: | May 7, 2010 |
| Last Updated: | July 5, 2012 |
| Health Authority: | United Kingdom: Research Ethics Committee |
Keywords provided by Plymouth Hospitals NHS Trust:
|
Harmonic scalpel ultrasonic scalpel LOTUS LigaSure |
vessel sealing burst pressure collateral damage |
Additional relevant MeSH terms:
|
Glucuronyl glucosamine glycan sulfate Anticoagulants Hematologic Agents Therapeutic Uses Pharmacologic Actions Hypolipidemic Agents Antimetabolites |
Molecular Mechanisms of Pharmacological Action Lipid Regulating Agents Fibrinolytic Agents Fibrin Modulating Agents Cardiovascular Agents Hypoglycemic Agents Physiological Effects of Drugs |
ClinicalTrials.gov processed this record on May 19, 2013