Multisite Pacing With a Quadripolar Lead
This study has been completed.
Sponsor:
St. Jude Medical
Information provided by (Responsible Party):
St. Jude Medical
ClinicalTrials.gov Identifier:
NCT00964938
First received: May 25, 2009
Last updated: March 24, 2012
Last verified: March 2012
- Full Text View
- Tabular View
- No Study Results Posted
- Disclaimer
- How to Read a Study Record
Purpose
The purpose of this study is to evaluate the effects of multisite left ventricular (LV) biventricular (BiV) pacing on LV hemodynamics in CRT patients. It is hypothesized that the effect of simultaneous BiV pacing utilizing multisite LV pacing on LV hemodynamics will be superior to conventional BiV pacing.
| Condition | Intervention | Phase |
|---|---|---|
|
Heart Failure |
Device: Quadripolar LV lead (pacing configurations) |
Phase 4 |
| Study Type: | Interventional |
| Study Design: | Allocation: Non-Randomized Intervention Model: Single Group Assignment Masking: Open Label |
| Official Title: | Multisite Pacing With a Quadripolar Left Heart Lead in Cardiovascular Resynchronization Therapy (CRT) Patients |
Resource links provided by NLM:
Further study details as provided by St. Jude Medical:
Primary Outcome Measures:
- dP/dt max [ Time Frame: acute: during implant procedure; 1 day ] [ Designated as safety issue: Yes ]
| Enrollment: | 35 |
| Study Start Date: | August 2009 |
| Primary Completion Date: | April 2011 (Final data collection date for primary outcome measure) |
Intervention Details:
-
Device: Quadripolar LV lead (pacing configurations)
Quadripolar LV lead will be used to deliver a combination of pacing configurations
Eligibility| Ages Eligible for Study: | 18 Years and older |
| Genders Eligible for Study: | Both |
| Accepts Healthy Volunteers: | No |
Criteria
Inclusion Criteria:
- Have a scheduled CRT implantation at the participating clinical study site
- Have NYHA functional class III or IV, ejection fraction less than or equal to 35%, and QRS duration greater than 120ms
- Be undergoing a new St. Jude Medical CRT-D device system (including LV lead) implantation
- Have the ability to provide informed consent for study participation and be willing and able to comply with the prescribed perioperative evaluations
Exclusion Criteria:
- Have persistent or permanent atrial fibrillation
- Have an intrinsic heart rate of <50 beats per minute
- Have a recent myocardial infarction within 40 days prior to enrollment
- Have undergone cardiac surgery or coronary revascularization procedure within 3 months prior to enrollment or be scheduled for such procedures
- Have had a recent CVA or TIA within 3 months prior to enrollment
- Have had intravenous inotropic support in the last 30 days
- Have ischemic etiology and are unable to tolerate stress echocardiography
Contacts and Locations
More Information
No publications provided
| Responsible Party: | St. Jude Medical |
| ClinicalTrials.gov Identifier: | NCT00964938 History of Changes |
| Other Study ID Numbers: | MSLV |
| Study First Received: | May 25, 2009 |
| Last Updated: | March 24, 2012 |
| Health Authority: | Canada: Health Canada |
Keywords provided by St. Jude Medical:
|
Hemodynamic response Cardiac resynchronization therapy |
Additional relevant MeSH terms:
|
Heart Failure Heart Diseases Cardiovascular Diseases |
ClinicalTrials.gov processed this record on May 23, 2013