Hybrid Operation in Thoracic Aortic Dissection
| Tracking Information | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| First Received Date ICMJE | December 22, 2011 | ||||||||||||||||||||||||
| Last Updated Date | January 12, 2012 | ||||||||||||||||||||||||
| Start Date ICMJE | November 2011 | ||||||||||||||||||||||||
| Estimated Primary Completion Date | December 2014 (final data collection date for primary outcome measure) | ||||||||||||||||||||||||
| Current Primary Outcome Measures ICMJE |
Cumulative MACE [ Time Frame: 12 months ] [ Designated as safety issue: Yes ] Cumulative MACE (including death, rupture, paraplegia, aneurysm formation et al) |
||||||||||||||||||||||||
| Original Primary Outcome Measures ICMJE | Same as current | ||||||||||||||||||||||||
| Change History | Complete list of historical versions of study NCT01500395 on ClinicalTrials.gov Archive Site | ||||||||||||||||||||||||
| Current Secondary Outcome Measures ICMJE |
|
||||||||||||||||||||||||
| Original Secondary Outcome Measures ICMJE | Same as current | ||||||||||||||||||||||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||||||||||||||||||||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||||||||||||||||||||||
| Descriptive Information | |||||||||||||||||||||||||
| Brief Title ICMJE | Hybrid Operation in Thoracic Aortic Dissection | ||||||||||||||||||||||||
| Official Title ICMJE | Hybrid Operation in Thoracic Aortic Dissection---Registry of China | ||||||||||||||||||||||||
| Brief Summary | The purpose of this study is to investigate the short to mid term efficacy and safety of different hybrid operations who had complex aortic lesions, such as ascending aortic/arch aneurysm, pseudo-aneurysm, Stanford Type A dissection, retrograde Stanford Type B dissection, dissection with primary tear located in the aortic arch, et al. |
||||||||||||||||||||||||
| Detailed Description | Aneurysms and dissection involving the ascending aorta and aortic arch have historically been treated with open surgical techniques, requiring cardiopulmonary bypass and deep hypothermic circulatory arrest (DHCA). Despite increasing experience and refinement of these procedures, there remains a substantial rate of morality and morbidity. The goal of hybrid operations is to re-construct the ascending aorta and aortic arch to cover the primary entry tear of the dissection and to remodel the aorta. Hybrid Operations including debranching technique+Thoracic Endovascular Aortic Repair (TEVAR), Frozen elephant trunk technique, aortic arch replacement with concommitant TEVAR, et al. The purpose of this study is to investigate the short to mid term efficacy and safety of different hybrid operations who had complex aortic lesions, such as ascending aortic/arch aneurysm, pseudo-aneurysm, Stanford Type A dissection, retrograde Stanford Type B dissection, dissection with primary tear located in the aortic arch, et al. Primary outcome measure is all-cause mortality. Secondary outcome variables include conversion to stent and/or surgery, induced thrombosis of the false lumen, cardiovascular morbidity, aortic expansion (>5 mm/y of maximum diameter including true and false lumina), quality of life, and length of intensive care unit and hospital stay. The study designs to enroll 50 patients to be monitored for 24 months. |
||||||||||||||||||||||||
| Study Type ICMJE | Interventional | ||||||||||||||||||||||||
| Study Phase | Not Provided | ||||||||||||||||||||||||
| Study Design ICMJE | Endpoint Classification: Safety/Efficacy Study Intervention Model: Single Group Assignment Masking: Single Blind (Subject) Primary Purpose: Treatment |
||||||||||||||||||||||||
| Condition ICMJE |
|
||||||||||||||||||||||||
| Intervention ICMJE | Procedure: Hybrid operation
Hybrid Operations including debranching technique+Thoracic Endovascular Aortic Repair (TEVAR), Frozen elephant trunk technique, aortic arch replacement with concommitant TEVAR, et al. Devices include Medtronic Stent Graft(Medtronic Medtronic, Inc., US) Microport Stent Graft(Microport Co.,LTD.,Shanghai, China) Ankura Stent Graft(Lifetech Scientific Co.,LTD.,Shenzhen, China).
Other Names:
|
||||||||||||||||||||||||
| Study Arm (s) | Experimental: Stent Graft and open surgery
Hybrid Operations including debranching technique+Thoracic Endovascular Aortic Repair (TEVAR), Frozen elephant trunk technique, aortic arch replacement with concommitant TEVAR, et al.
Intervention: Procedure: Hybrid operation |
||||||||||||||||||||||||
| Publications * | Not Provided | ||||||||||||||||||||||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||||||||||||||||||||||
| Recruitment Information | |||||||||||||||||||||||||
| Recruitment Status ICMJE | Recruiting | ||||||||||||||||||||||||
| Estimated Enrollment ICMJE | 50 | ||||||||||||||||||||||||
| Estimated Completion Date | December 2015 | ||||||||||||||||||||||||
| Estimated Primary Completion Date | December 2014 (final data collection date for primary outcome measure) | ||||||||||||||||||||||||
| Eligibility Criteria ICMJE | Inclusion CriteriaInclusion Criteria:
Exclusion Criteria:
|
||||||||||||||||||||||||
| Gender | Both | ||||||||||||||||||||||||
| Ages | 12 Years to 90 Years | ||||||||||||||||||||||||
| Accepts Healthy Volunteers | No | ||||||||||||||||||||||||
| Contacts ICMJE |
|
||||||||||||||||||||||||
| Location Countries ICMJE | China | ||||||||||||||||||||||||
| Administrative Information | |||||||||||||||||||||||||
| NCT Number ICMJE | NCT01500395 | ||||||||||||||||||||||||
| Other Study ID Numbers ICMJE | XJ-20111126 -2 | ||||||||||||||||||||||||
| Has Data Monitoring Committee | Yes | ||||||||||||||||||||||||
| Responsible Party | Xijing Hospital | ||||||||||||||||||||||||
| Study Sponsor ICMJE | Xijing Hospital | ||||||||||||||||||||||||
| Collaborators ICMJE |
|
||||||||||||||||||||||||
| Investigators ICMJE |
|
||||||||||||||||||||||||
| Information Provided By | Xijing Hospital | ||||||||||||||||||||||||
| Verification Date | January 2012 | ||||||||||||||||||||||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||||||||||||||||||||||