Clinical Evaluation of e- Ab Sensor - Based Real-time Diagnosis of Serum Procalcitonin Level
| Tracking Information | |||||
|---|---|---|---|---|---|
| First Received Date ICMJE | July 1, 2011 | ||||
| Last Updated Date | November 15, 2012 | ||||
| Start Date ICMJE | November 2010 | ||||
| Primary Completion Date | July 2012 (final data collection date for primary outcome measure) | ||||
| Current Primary Outcome Measures ICMJE |
Performance of e- Ab sensor for serum PCT level measurement [ Time Frame: 1 Day ] [ Designated as safety issue: No ] The serum procalcitonin level from e- Ab sensor would be compared with the results from Kryptor assay system, Brahms, Germany. The correlation between serum procalcitonin levels from e- Ab sensor and from Kryptor assay system would be examined. |
||||
| Original Primary Outcome Measures ICMJE | Same as current | ||||
| Change History | Complete list of historical versions of study NCT01388114 on ClinicalTrials.gov Archive Site | ||||
| Current Secondary Outcome Measures ICMJE | Not Provided | ||||
| Original Secondary Outcome Measures ICMJE | Not Provided | ||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||
| Descriptive Information | |||||
| Brief Title ICMJE | Clinical Evaluation of e- Ab Sensor - Based Real-time Diagnosis of Serum Procalcitonin Level | ||||
| Official Title ICMJE | Clinical Evaluation of e- Ab Sensor - Based Real-time Diagnosis of Serum Procalcitonin Level | ||||
| Brief Summary | The purpose of this study is to develop a real-time diagnostic technique with e- Ab sensor for serum PCT level measurement will offer a test with lower cost, and increase the applicability of serum Procalcitonin (PCT) level in daily clinical practice. |
||||
| Detailed Description | Sepsis is a clinical syndrome with complex interactions between microorganism, host immune, inflammatory and coagulation response. The mortality rate associated with septic shock is high, up to 40-70%. Currently, the diagnosis of sepsis depends on microbial infection and systemic inflammatory response syndrome, which lacks sensitivity and specificity. Accordingly, Society of Critical Care Medicine (SCCM) offered new recommendations about the diagnosis of sepsis in 2001, which included the serum level of procalcitonin (PCT). Increased PCT levels through the clinical course correlated with higher mortality in critically-ill patients. On the other hand, recent studies also showed PCT levels could guide the antibiotic treatment in patients with sepsis or lower respiratory tract infection. Besides usage in sepsis population, serum PCT level could also be used for aids in diagnosis of bacterial infection and for guide of antibiotic treatment in acute exacerbation of chronic obstructive airway disease. However, current method of PCT assay depends on the Kryptor system developed by BRAHMS, Germany, with the functional sensitivity of 60 pg/mL. Each assay costs 1300 NT dollars, which is too expensive for serial follow-up of serum PCT levels. A real-time diagnostic technique with e- Ab sensor for serum PCT level measurement will offer a test with lower cost, and increase the applicability of serum PCT level in daily clinical practice. Here, the investigators conduct a study to develop a real-time diagnostic technique with e- Ab sensor for serum PCT level measurement in patients with sepsis. |
||||
| Study Type ICMJE | Interventional | ||||
| Study Phase | Not Provided | ||||
| Study Design ICMJE | Intervention Model: Single Group Assignment Masking: Open Label Primary Purpose: Diagnostic |
||||
| Condition ICMJE | Sepsis | ||||
| Intervention ICMJE | Device: Electrosensing Antibody Probe System (e- Ab sensing)
Electrosensing antibody probing system (e- Ab sensing), which was developed for the rapid and sensitive detection of hapten, proteins or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-procalcitonin antibody and procalcitonin in the serum of the patients. The system incorporates the use of engineered semiconductive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats. In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe which specifically and selectively binds procalcitonin polypeptide target molecules in the test specimen |
||||
| Study Arm (s) | Experimental: Electrosensing antibody probing system (e- Ab sensing)
Intervention: Device: Electrosensing Antibody Probe System (e- Ab sensing) |
||||
| Publications * | Not Provided | ||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||
| Recruitment Information | |||||
| Recruitment Status ICMJE | Completed | ||||
| Enrollment ICMJE | 200 | ||||
| Completion Date | July 2012 | ||||
| Primary Completion Date | July 2012 (final data collection date for primary outcome measure) | ||||
| Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
||||
| Gender | Both | ||||
| Ages | 18 Years and older | ||||
| Accepts Healthy Volunteers | No | ||||
| Contacts ICMJE | Contact information is only displayed when the study is recruiting subjects | ||||
| Location Countries ICMJE | Taiwan | ||||
| Administrative Information | |||||
| NCT Number ICMJE | NCT01388114 | ||||
| Other Study ID Numbers ICMJE | 201010020R | ||||
| Has Data Monitoring Committee | No | ||||
| Responsible Party | National Taiwan University Hospital | ||||
| Study Sponsor ICMJE | National Taiwan University Hospital | ||||
| Collaborators ICMJE | Not Provided | ||||
| Investigators ICMJE |
|
||||
| Information Provided By | National Taiwan University Hospital | ||||
| Verification Date | November 2012 | ||||
|