S-ICD® System IDE Clinical Study

This study is ongoing, but not recruiting participants.
Sponsor:
Information provided by (Responsible Party):
Cameron Health, Inc.
ClinicalTrials.gov Identifier:
NCT01064076
First received: February 4, 2010
Last updated: October 8, 2012
Last verified: October 2012

February 4, 2010
October 8, 2012
January 2010
October 2011   (final data collection date for primary outcome measure)
  • Safety: The 180-day S-ICD System complication-free rate meets or exceeds the performance goal of 79%. [ Time Frame: 180 days ] [ Designated as safety issue: Yes ]
  • Effectiveness: The induced VF conversion efficacy rate meets or exceeds the performance goal of 88%. [ Time Frame: Implant/Pre-Discharge ] [ Designated as safety issue: No ]
Same as current
Complete list of historical versions of study NCT01064076 on ClinicalTrials.gov Archive Site
Not Provided
Not Provided
Not Provided
Not Provided
 
S-ICD® System IDE Clinical Study
S-ICD® System Clinical Investigation

This clinical study is designed to evaluate the safety and effectiveness of the subcutaneous implantable defibrillator (S-ICD) System.

This clinical study is a prospective, non-randomized, multicenter clinical study without a control group conducted in the United States, Europe, and New Zealand.

Patients meeting eligibility criteria for implanting an S-ICD System will be enrolled in this clinical study, implanted with an S-ICD System, and followed prior to hospital discharge, and post-implant at 30 days, 90 days, and 180 days. After the 180-day post-implant follow-up visit, patients will continue to be followed semi-annually until study closure.

Eligible patients enrolled in this clinical study may also participate in the chronic conversion sub-study.

The safety endpoint will be evaluated through the use of a 180-day S-ICD System complication-free rate. The effectiveness endpoint will be evaluated using an induced ventricular fibrillation (VF) conversion efficacy rate. Spontaneous episodes and chronic conversion testing data will be evaluated using descriptive statistics to provide additional data supporting the continued chronic performance of the S-ICD System.

Interventional
Not Provided
Endpoint Classification: Safety/Efficacy Study
Intervention Model: Single Group Assignment
Masking: Open Label
Primary Purpose: Treatment
Tachycardia, Ventricular
Device: S-ICD System
The S-ICD System is an implantable technology that uses a subcutaneous pulse generator and subcutaneous electrode system to treat ventricular tachyarrhythmias. The S-ICD System consists of the SQ-RX pulse generator (Model 1010), the Q-TRAK subcutaneous electrode (Model 3010), the Q-TECH programmer (Model 2020), and Q-GUIDE electrode insertion tools (Models 4010 and 4020).
Other Names:
  • SQ-RX Pulse Generator
  • Q-TRAK Subcutaneous Electrode
  • Q-GUIDE Electrode Insertion Tools
  • Q-TECH Programmer
Experimental: S-ICD System
This is a single arm study
Intervention: Device: S-ICD System
Not Provided

*   Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline.
 
Active, not recruiting
330
October 2013
October 2011   (final data collection date for primary outcome measure)

Inclusion Criteria:

  • For patients without an existing transvenous device

    • Patient meets Class I, Class IIa or Class IIb indications/recommendations for ICD implantation per the current published guidelines at the time of enrollment

  • For patients with an existing transvenous device

    • Patient requires replacement or revision of an existing implanted transvenous ICD system

  • Age is ≥ 18 years
  • An appropriate pre-operative ECG per template provided

Exclusion Criteria:

  • Any condition which precludes the subject's ability to comply with the study requirements, including completion of the study.
  • Females who are pregnant or lactating and pre-menopausal women who are unwilling to use adequate birth control for the duration of the study.
  • Participation in any other investigational study without prior written consent from the study sponsor.
  • Patients with a serious medical condition and life expectancy of less than one year.
  • Patients with documented spontaneous and frequently recurring VT that is reliably terminated with anti-tachycardia pacing, unless the patient is not a candidate for a transvenous ICD system.
  • Patients with existing epicardial patches or subcutaneous electrodes in the left thoracic quadrant.
  • Patients with unipolar pacemakers or implanted devices that revert to unipolar pacing.
  • Patients with severely impaired kidney function as measured by a Cockcroft-Gault Glomerular Filtration Rate (GFR) with an estimated GFR ≤ 29.
Both
18 Years and older
No
Contact information is only displayed when the study is recruiting subjects
United States,   Netherlands,   New Zealand,   United Kingdom
 
NCT01064076
DN-03909
Yes
Cameron Health, Inc.
Cameron Health, Inc.
Not Provided
Study Director: Jon Hunt, Ph.D. Cameron Health, Inc.
Cameron Health, Inc.
October 2012

ICMJE     Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP