Freehand Ultrasound Elasticity Imaging in Liver Surgery (IOUS)
| Tracking Information | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| First Received Date ICMJE | July 17, 2009 | ||||||||
| Last Updated Date | August 5, 2011 | ||||||||
| Start Date ICMJE | September 2007 | ||||||||
| Estimated Primary Completion Date | September 2011 (final data collection date for primary outcome measure) | ||||||||
| Current Primary Outcome Measures ICMJE |
Comparison of transverse ablation diameter between intraoperative ultrasound elasticity imaging (USEI) and postoperative cross-sectional imaging (CT or MRI). [ Time Frame: 2 years ] [ Designated as safety issue: No ] | ||||||||
| Original Primary Outcome Measures ICMJE | Same as current | ||||||||
| Change History | Complete list of historical versions of study NCT00942383 on ClinicalTrials.gov Archive Site | ||||||||
| Current Secondary Outcome Measures ICMJE |
|
||||||||
| Original Secondary Outcome Measures ICMJE | Same as current | ||||||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||||||
| Descriptive Information | |||||||||
| Brief Title ICMJE | Freehand Ultrasound Elasticity Imaging in Liver Surgery | ||||||||
| Official Title ICMJE | Application of Novel, High Resolution, and Freehand Ultrasound Elasticity Imaging in Liver Surgery | ||||||||
| Brief Summary | The purpose of this study is to investigate the potential for visualizing radiofrequency-induced (RFA) and microwave-induced (MWA) hepatic thermal ablation lesions using a novel, high resolution, and freehand ultrasound elasticity imaging method in human subjects. |
||||||||
| Detailed Description | Study Procedures This is a prospective cohort study. Data will be collected from patients who have signed an informed consent form and are undergoing open, laparoscopic, or percutaneous RFA or MWA as their treatment for liver tumors. Their images will be assembled and correlated according to their IOUS characteristics plus processed strain images. Below is the description of how each aim will be accomplished. Aim-1: Ultrasound Elasticity Imaging Acquisition. USEI data (both raw US data and B-mode data) will be recorded during standard operative ultrasound imaging used to guide thermal ablative therapy in the operating room. Images will be acquired before, during, and after RFA or MWA therapy. Raw data acquisition will be conducted using a Siemens Antares US scanner (Siemens Medical Solutions USA, Inc. Ultrasound Division, Issaquah, WA) with an ultrasound research interface (URI) to access raw US data. A Siemens VF 10-5 linear array will be used to acquire data using manual handling. Typically, the ultrasound probe is tracked and spatially registered with the coordinate frame of the of the CT images, so the pixels of the B-mode images are known in the coordinate frame of the CT volume. Thus if one localizes the target anatomy in the B-mode images, then the position of the target is automatically known with respect to the CT volume for validation of the performance of the elastography. The tracking beams are standard B-mode pulses (6.67 MHz center frequency, F/1.5 focal configuration, apodized, pulse repetition frequency (PRF) of 10.6 KHz, with a pulse length of 0.3μs). This US device is one of the standard machines available for clinical US. We will track the ultrasound probe with an Electro-Magnetic (EM) tracker. The tracker has small sensors that can be attached to the ultrasound probe under the sterile cover of the ultrasound probe, and therefore the sensor is not exposed. Also, the tracker has a 'transmitter' that is flat and is placed underneath the patient below a soft cushion. The sensor is attached to the ultrasound probe prior to the surgery and hencethe probe will remain sterile. The transmitter is flat and will be placed under a soft cushion so that it does not cause any pressure effects on patient. In both cases (raw data and B-mode), the freehand acquisition should allow for palpation (manual compression within few millimeters). Risks and discomforts are negligible: Interventional ultrasound is FDA-approved, and we will use only the data resulting from standard of care use of clinically certified equipment. The maximum length of a data recording session will be 1-2 minutes during standard ultrasound acquisition. We will acquire cine sequences for five defined periods: 1) tumor imaging before probe placement; 2) immediately after probe placement; 3) near completion during ablation; 4) two minutes following ablation with probe in place; and 5) after removing the ablator probe. |
||||||||
| Study Type ICMJE | Interventional | ||||||||
| Study Phase | Not Provided | ||||||||
| Study Design ICMJE | Endpoint Classification: Efficacy Study Intervention Model: Single Group Assignment Masking: Open Label Primary Purpose: Diagnostic |
||||||||
| Condition ICMJE | Liver Tumors | ||||||||
| Intervention ICMJE | Device: IOUS - Siemens Anteras
additional IOUS to acquire ultrasound elasticity imaging |
||||||||
| Study Arm (s) | Experimental: IOUS-USEI
Receive additional intraoperative ultrasound using the Siemens Anteras to acquire ultrasound elasticity imaging plus standard of care intraoperative ultrasound
Intervention: Device: IOUS - Siemens Anteras |
||||||||
| Publications * | Not Provided | ||||||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||||||
| Recruitment Information | |||||||||
| Recruitment Status ICMJE | Recruiting | ||||||||
| Estimated Enrollment ICMJE | 40 | ||||||||
| Estimated Completion Date | September 2013 | ||||||||
| Estimated Primary Completion Date | September 2011 (final data collection date for primary outcome measure) | ||||||||
| Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
||||||||
| Gender | Both | ||||||||
| Ages | 18 Years and older | ||||||||
| Accepts Healthy Volunteers | No | ||||||||
| Contacts ICMJE |
|
||||||||
| Location Countries ICMJE | United States | ||||||||
| Administrative Information | |||||||||
| NCT Number ICMJE | NCT00942383 | ||||||||
| Other Study ID Numbers ICMJE | J0765, NA_00011327 | ||||||||
| Has Data Monitoring Committee | Yes | ||||||||
| Responsible Party | Michael Choti, Sidney Kimmel Comprehensive Cancer Center | ||||||||
| Study Sponsor ICMJE | Sidney Kimmel Comprehensive Cancer Center | ||||||||
| Collaborators ICMJE | Not Provided | ||||||||
| Investigators ICMJE |
|
||||||||
| Information Provided By | Sidney Kimmel Comprehensive Cancer Center | ||||||||
| Verification Date | August 2011 | ||||||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||||||