Study Evaluating Safety Of Patients Switching To ReFacto AF In Usual Care Settings

This study has been terminated.
(See termination reason in detailed description.)
Sponsor:
Information provided by (Responsible Party):
Pfizer
ClinicalTrials.gov Identifier:
NCT00884390
First received: April 16, 2009
Last updated: April 24, 2013
Last verified: April 2013

April 16, 2009
April 24, 2013
May 2009
March 2013   (final data collection date for primary outcome measure)
Development of clinically significant factor VIII inhibitors [ Time Frame: 100 exposure days to study medication (approx. 2 years) ] [ Designated as safety issue: Yes ]
Inhibitor Development [ Time Frame: 2 years ] [ Designated as safety issue: Yes ]
Complete list of historical versions of study NCT00884390 on ClinicalTrials.gov Archive Site
  • Occurence of adverse events and serious adverse events during the study [ Time Frame: Duration of participation in study ] [ Designated as safety issue: Yes ]
  • Annualized bleed rates [ Time Frame: Duration of participation in study ] [ Designated as safety issue: No ]
  • Response to first on-demand treatment with test article for all new bleeding episodes [ Time Frame: Duration of participation in study ] [ Designated as safety issue: No ]
  • number of test article infusions required for each bleeding episode [ Time Frame: Duration of participation in study ] [ Designated as safety issue: No ]
  • number of breakthrough bleeding episodes within 48 hours of a prophylaxis treatment [ Time Frame: Duration of participation in study ] [ Designated as safety issue: No ]
  • Average infusion dose and the total factor consumption [ Time Frame: Duration of participation in study ] [ Designated as safety issue: No ]
  • Incidence of less-than-expected-therapeutic effect (LETE) [ Time Frame: Duration of participation in study ] [ Designated as safety issue: No ]
Not Provided
Not Provided
Not Provided
 
Study Evaluating Safety Of Patients Switching To ReFacto AF In Usual Care Settings
A Postauthorization Safety Surveillance Study Of Patients Switching To ReFacto AF From ReFacto Or Other Factor VIII Products In Usual Care Settings

The study will be investigating safety in patients who switch to ReFacto AF from ReFacto and other Factor VIII products.

The trial was terminated prematurely on 28 March 2013, due to the inability to recruit the planned number of subjects. The decision to terminate the trial was not based on any safety or efficacy concerns and agreement to close the study in March 2013 was agreed with EMA prior to closure activity.

Interventional
Phase 4
Allocation: Non-Randomized
Endpoint Classification: Safety/Efficacy Study
Intervention Model: Single Group Assignment
Masking: Open Label
Primary Purpose: Treatment
Hemophilia A
  • Drug: moroctocog alfa (AF-CC) (ReFacto AF)
    Providing moroctocog alfa (AF-CC) as test article for use during this study.
  • Procedure: Laboratory tests
    Laboratory samples are collected during study visits, in order to collect safety and efficacy data related to the administration of test article.
Experimental: ReFacto AF
Interventions:
  • Drug: moroctocog alfa (AF-CC) (ReFacto AF)
  • Procedure: Laboratory tests
Not Provided

*   Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline.
 
Terminated
224
March 2013
March 2013   (final data collection date for primary outcome measure)

Inclusion Criteria:

  • Male patients greater than or equal to 12 years of age with severe hemophilia A (FVIII:C less than 1%).
  • Treatment history of greater than 150 EDs to prior recombinant or plasma-derived FVIII replacement products.
  • Transitioning to ReFacto AF from ReFacto or other recombinant or plasma-derived FVIII replacement products.
  • Serum albumin greater than or equal to the lower limit of normal (LLN).
  • Platelet count greater than or equal to 100,000/µL.
  • Prothrombin time (PT) less than or equal to1.25 × ULN, or international normalized ratio (INR) less than or equal to 1.5.
  • HIV positive subjects must have a CD4 count greater than 200/µL and HIV viral load less than 200 particles/µL.

Exclusion Criteria:

  • Presence of any bleeding disorder in addition to hemophilia A.
  • A positive FVIII inhibitor, according to the local laboratory, at screening; or any Bethesda Inhibitor Titer greater than 0.6, regardless of the normal range for the testing laboratory.
  • Treated with immunomodulatory therapy (including Immune Tolerance Induction [ITI]) during the screening period.
  • Prior exposure to moroctocog alfa (AF-CC).
  • Known hypersensitivity to hamster protein.
Male
12 Years and older
No
Contact information is only displayed when the study is recruiting subjects
Austria,   Belgium,   Denmark,   Finland,   France,   Germany,   Greece,   Hungary,   Italy,   Netherlands,   Romania,   Spain,   Sweden,   United Kingdom
 
NCT00884390
3082B2-4432
No
Pfizer
Pfizer
Not Provided
Study Director: Pfizer CT.gov Call Center Pfizer
Pfizer
April 2013

ICMJE     Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP