3D Imaging of the Hip Using DXA (3DScans)

The recruitment status of this study is unknown because the information has not been verified recently.
Verified July 2011 by Sheffield Teaching Hospitals NHS Foundation Trust.
Recruitment status was  Active, not recruiting
Sponsor:
Collaborators:
Medical Research Council
Hologic, Inc.
Information provided by:
Sheffield Teaching Hospitals NHS Foundation Trust
ClinicalTrials.gov Identifier:
NCT00666640
First received: April 23, 2008
Last updated: July 20, 2011
Last verified: July 2011

April 23, 2008
July 20, 2011
May 2008
January 2011   (final data collection date for primary outcome measure)
To establish the diagnostic accuracy for hip fracture of the 3D HipTM and SEMs derived from the 3D HipTM, and to determine how much better the 3D HipTM is over the traditional 2D DXA in a case controlled study. [ Time Frame: 2 years ] [ Designated as safety issue: No ]
Same as current
Complete list of historical versions of study NCT00666640 on ClinicalTrials.gov Archive Site
The secondary outcome measures are parameters related to the hip structure, such as volumetric bone mineral density, cross sectional area, moment of inertia, section modulus, cortical thickness and buckling ratio. [ Time Frame: 2 years ] [ Designated as safety issue: No ]
Same as current
Not Provided
Not Provided
 
3D Imaging of the Hip Using DXA
Parameters Derived From DXA-based Structural Engineering Models of the Proximal Femur as a Biomarker for Hip Fracture Prediction.

The study aims to determine the efficacy and best methods for predicting hip fractures and diagnosing post-menopausal osteoporosis using three dimensional structural engineering models (SEMs) of proximal femoral bone produced using a Hologic Discovery duel-energy x-ray absorptiometry scanner and Hologic's new 3D Hip(TM) software in comparison to three dimensional SEMs produced using quantitative computed tomography - the current gold standard.

Bone mineral density (BMD) measurements by dual-energy x-ray absorptiometry (DXA) have been available to the clinician for the past 20 years and their use forms the basis of current clinical practice guidelines. The measurements are very useful, but they could be improved upon by taking into account the third dimension of bone (depth) and the distribution of mineral within bone. The value of a diagnostic test depends greatly on the strength of association of the measurement with the outcome. If we find that our new approach strengthens the ability of hip DXA measurements to predict fracture then we will have a greatly improved diagnostic test and so can better identify those patients we should treat. Further, such a test would allow better evaluation of new therapies for osteoporosis, particularly those that may alter bone geometry, including anabolic agents such as teriparatide.

Patients attending for study visits will complete a basic questionnaire to collect information on their bone health and lifestyle (the current Metabolic Bone Centre standard questionnaire). Patients will also undergo DXA scans of their hips on a Hologic Discovery DXA machine using a new 3D imaging technique called '3D HipTM'. Hologic will process 3D HipTM scans and provide us with volumetric dataset of the scans before they provide us with a high performance PC and software for us to do the process on-site. They have already installed the software upgrade and necessary hardware to our Discovery densitometry system to enhance the 3D HipTM capability. Patients will attend for a CT scan of their hip at the medical imaging department of the Northern General Hosptial as per standard practice.

50 postmenopausal women who have recently suffered a hip fracture will be recruited to the study. 50 postmenopausal age matched controls will also be recruited. Subjects will give informed consent and a study visit will be arranged for them to attend for a DXA scan and a CT scan. At the study visit basic demographic data and a brief medical history will be collected on study specific Case Report Forms (CRF).

The intended outcomes of the study are 1) To establish the diagnostic accuracy for hip fracture of the 3D HipTM and SEMs derived from the 3D HipTM, and to determine how much better the 3D HipTM is over the traditional 2D DXA in a case controlled study. 2) To compare three dimensional SEMs of the proximal femur derived from 3D Hip(TM) against simulated SEMs derived using quantitative computed tomography.

Observational
Observational Model: Case Control
Time Perspective: Prospective
Not Provided
Not Provided
Non-Probability Sample

Community Sample Subjects recruited from A+E attendances/fracture clinics at Sheffield hospitals

  • Osteoporosis
  • Low-energy Trauma Fracture
  • Device: DXA scan of hip
    Dual-energy X-ray Absorptiometry scan
  • Device: CT scan of hip
    Computed Tomography scan
  • 1
    50 subjects who have suffered a hip fracture
    Interventions:
    • Device: DXA scan of hip
    • Device: CT scan of hip
  • 2
    50 age matched controls
    Interventions:
    • Device: DXA scan of hip
    • Device: CT scan of hip
Not Provided

*   Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline.
 
Active, not recruiting
100
January 2012
January 2011   (final data collection date for primary outcome measure)

Inclusion Criteria:

  • be female
  • at least 5 years post menopausal but <85 years
  • be sufficiently mobile to undergo DXA and QCT scanning
  • be able and willing to participate in the study and provide written informed consent

Exclusion Criteria:

  • bi-lateral hip replacement
  • have hip replacement on the non-fractured side
  • have any history of cancer within the past 5 years excluding skin cancer non melanomas
  • have a history of ongoing conditions or diseases known to cause abnormalities of calcium metabolism or skeletal health (secondary osteoporosis)
  • have a history of chronic renal disease (as defined by a creatinine clearance of ≤ 30ml/min)
  • Acute or chronic hepatic disease
  • Malabsorption syndromes
  • Hyperthyroidism as manifested by TSH outside the lower limit of the normal range
  • Hyperparathyroidism
  • Hypocalcemia or hypercalcemia
  • Osteomalacia
  • Cushing's syndrome
  • patients who are currently on glucocorticoid therapy
  • have a history of any known condition that would interfere with the assessment of DXA or CT of hip
  • have markedly abnormal clinical laboratory parameters that are assessed as clinically significant by the investigator
  • have participated in another clinical trial involving active therapy 3 months prior to randomisation
  • have a known confusional state or dementia as documented in hospital notes, or be unsuitable for approach in the opinion of the physician with duty of care
Female
50 Years to 85 Years
Yes
Contact information is only displayed when the study is recruiting subjects
United Kingdom
 
NCT00666640
STH14748
No
Professor Richard Eastell, University of Sheffield
Sheffield Teaching Hospitals NHS Foundation Trust
  • Medical Research Council
  • Hologic, Inc.
Study Director: Lang Yang, Dr Sheffield University
Study Director: Eugene McCloskey, Dr Sheffield University
Sheffield Teaching Hospitals NHS Foundation Trust
July 2011

ICMJE     Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP