Efficacy Study of CytoSorb Hemoperfusion Device on IL-6 Removal in ARDS/ALI Patients With Sepsis
| Tracking Information | |||||
|---|---|---|---|---|---|
| First Received Date ICMJE | November 14, 2007 | ||||
| Last Updated Date | June 6, 2011 | ||||
| Start Date ICMJE | November 2007 | ||||
| Primary Completion Date | April 2011 (final data collection date for primary outcome measure) | ||||
| Current Primary Outcome Measures ICMJE |
Relative IL-6 levels as a percent (%) of baseline will be lower in subjects receiving CytoSorb treatment in conjunction with the standard of care as compared to control subjects receiving only the standard of care for ARDS/ALI in the setting of sepsis. [ Time Frame: 7 Days ] [ Designated as safety issue: No ] | ||||
| Original Primary Outcome Measures ICMJE |
Relative IL-6 levels as a percent (%) of baseline will be lower in subjects receiving CytoSorb treatment in conjunction with the standard of care as compared to control subjects receiving only the standard of care for ARDS/ALI in the setting of sepsis. [ Time Frame: 7 Days ] | ||||
| Change History | Complete list of historical versions of study NCT00559130 on ClinicalTrials.gov Archive Site | ||||
| Current Secondary Outcome Measures ICMJE |
Ventilator Free Days, Reduction cytokines TNF-α, IL-1b, IL-10, CRP, 28-day all cause mortality, Oxygen Index (OI), P/F ratios, MODS scores [ Time Frame: 28 Days ] [ Designated as safety issue: No ] | ||||
| Original Secondary Outcome Measures ICMJE |
Ventilator Free Days, Reduction cytokines TNF-α, IL-8, IL-1, IL-10, IL-18, CRP, 28-day all cause mortality, Oxygen Index (OI), P/F ratios, MODS scores [ Time Frame: 28 Days ] | ||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||
| Descriptive Information | |||||
| Brief Title ICMJE | Efficacy Study of CytoSorb Hemoperfusion Device on IL-6 Removal in ARDS/ALI Patients With Sepsis | ||||
| Official Title ICMJE | Multi-Center, Efficacy Study of the MedaSorb CytoSorb™ Hemoperfusion Device as an Adjunctive Therapy in Subjects With Acute Respiratory Distress Syndrome (ARDS) or Acute Lung Injury (ALI) in the Setting of Sepsis | ||||
| Brief Summary | The hypothesis of this study is use of CytoSorb hemoperfusion device as an adjunctive therapy to the standard of care in treating ARDS/ALI patients in the setting of sepsis will result in improved clearance of cytokines when compared to control patients receiving only the standard of care. |
||||
| Detailed Description | Mortality rates from acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) range from 38.5 to 65%, with the lower mortality in acute lung injury than in ARDS. ARDS/ALI is most often seen as part of a systemic inflammatory response syndrome (SIRS), particularly systemic sepsis. The lung findings parallel the damage in other tissues, namely, widespread destruction of the capillary endothelium, extravasation of protein rich fluid and interstitial edema. The alveolar basement membrane becomes damaged and fluid leaks into the airspaces, reducing lung compliance and causing ventilation-perfusion mismatch. The most important causes of ALI/ARDS are sepsis, pneumonia, major trauma, pulmonary aspiration, near drowning, burns, inhalation of toxic gases (e.g. ammonia), fat embolism, amniotic fluid embolism, eclampsia, drug intoxication (e.g. aspirin), radiation injury and mechanical ventilation. Cox and colleagues have demonstrated in an ovine model of ARDS that there is intense acute inflammation in the trachea and bronchi from 3 to 48h after injury, with accumulation of neutrophils, fibrin and other plasma proteins, and mucus in airway lumens. Immunostaining for multiple cytokines (interleukin-8 (IL-8), IL-1beta, IL-1alpha, tumor necrosis factor-alpha (TNF-alpha), and vascular endothelial growth factor (VEGF)) are found in airway mucous glands, and the release of cytokines into the airway lumen are considered potentially highly significant in the progression of injury. The importance of cytokines is being increasingly realized in mechanical lung injury (a common cause of ALI/ARDS) associated with mechanical ventilation (MV). Here the pathway is identical with release of cytokines/chemokines which potentiate the extravasation, activation, and recruitment of leukocytes, causing ventilator-associated lung injury (VALI) and ventilator-induced lung injury (VILI). Moreover, VALI/VILI can perpetuate the chronic inflammatory response during ALI/ARDS and multiple organ dysfunction syndrome (MODS). The purpose of this study is to evaluate the reduction of cytokines, using the CytoSorb device, on primary and secondary endpoints |
||||
| Study Type ICMJE | Interventional | ||||
| Study Phase | Not Provided | ||||
| Study Design ICMJE | Allocation: Randomized Endpoint Classification: Safety/Efficacy Study Intervention Model: Parallel Assignment Masking: Open Label Primary Purpose: Treatment |
||||
| Condition ICMJE |
|
||||
| Intervention ICMJE | Device: CytoSorb Hemoperfusion
Daily hemoperfusion for 6 hours with CytoSorb device |
||||
| Study Arm (s) | Not Provided | ||||
| Publications * | Not Provided | ||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||
| Recruitment Information | |||||
| Recruitment Status ICMJE | Completed | ||||
| Estimated Enrollment ICMJE | 100 | ||||
| Completion Date | June 2011 | ||||
| Primary Completion Date | April 2011 (final data collection date for primary outcome measure) | ||||
| Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
||||
| Gender | Both | ||||
| Ages | 18 Years to 80 Years | ||||
| Accepts Healthy Volunteers | No | ||||
| Contacts ICMJE | Contact information is only displayed when the study is recruiting subjects | ||||
| Location Countries ICMJE | Germany | ||||
| Administrative Information | |||||
| NCT Number ICMJE | NCT00559130 | ||||
| Other Study ID Numbers ICMJE | 2007-01 | ||||
| Has Data Monitoring Committee | Yes | ||||
| Responsible Party | Dr. Robert Bartlett, MedaSorb Corp | ||||
| Study Sponsor ICMJE | MedaSorb Technologies, Inc | ||||
| Collaborators ICMJE | Not Provided | ||||
| Investigators ICMJE |
|
||||
| Information Provided By | MedaSorb Technologies, Inc | ||||
| Verification Date | June 2011 | ||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||