Correlation Research Study: IQ2, NcIQ and IQ101 (NMT-CT)
This study has been completed.
Study NCT00491777   Information provided by Noninvasive Medical Technologies, Inc.
First Received: June 22, 2007   No Changes Posted

June 22, 2007
June 22, 2007
June 2007
 
A direct correlation between output parameters of IQ2/NcIQ to IQ101
Same as current
No Changes Posted
 
 
 
Correlation Research Study: IQ2, NcIQ and IQ101
Correlation Study of NMT's IQ2, NcIQ and Its' Predicate Technology, IQ101.

The new NcIQ thoracic impedance monitor is based on the predicate device, the IQ101. The new model uses the same 3-dimensional signal averaging as the original device, but also include second radio frequency signal to permit the device to work “wirelessly”, i.e., without electrode lead attachments to the patient. This study seeks to 1) validate the use of the new device and confirm the correlation of the IQ101 and NcIQ. 2) Evaluate the ease of the new device.

The new IQ2 thoracic impedance monitor is based on the predicate device, the IQ101. The new model uses the same 3-dimensional signal averaging as the original device, but with smaller housing and updated operating software. This study seeks to 1) Validate the use of the new device and confirm the correlation of the IQ101 and IQ2. 2) Compare the ease of the devices.

The IQ101 is the first generation of the non invasive cardiograph. This device uses impedance to a micro-electric field passing from the electrodes. The NcIQ uses Radio frequencies and the same 3 dimensional signal averaging algorithm used in the IQ101 to generate hemodynamic data. The radio waves enables the device to work without the contact lead arrays used in the IQ2 and can take measurements without even contacting the patient, hence can be applied through clothing and is simple to apply. This makes the potential use by first responders a possibility. The device measures the change in the radio wave reflection during the cardiac cycle to estimate ardiac function. Specifically, it measures cardiac output, the amount of blood pumped per minute, and other hemodynamic parameters previously only measurable with invasive catheters. The data us used to generate a LIFESCORE and can measure and report dangerous trends to the caretaker. The device has a companion device to download the data for the hospital providers to create a seamless transfer of care. The new device uses technology similar to the previous generation machine but has been miniaturized, given updated operating system, and newer computer technology that helped make the device smaller, and faster. The underlying patented algorithm was not changed. Therefore, it is expected to provide the same degree of accuracy and precision as the predicate device.

The IQ101 is the first generation of the non invasive cardiograph. This device uses impedance to a micro-electric field passing from the electrodes. The device can use the impedance and the change in the impedance during the cardiac cycle to estimate thoracic fluid volumes and cardiac function. Specifically, it measures cardiac output, the amount of blood pumped per minute, and other hemodynamic parameters previously only measurable with invasive catheters. There are many studies documenting the device’s performance. The new device uses the same technology but has been modernized with updated operating system, and newer computer technology that helped make the device smaller, and faster. The device has also been redesigned to make operator use simpler and reduce the number wires involved. The underlying patented algorithm was not changed. Therefore, it is expected to provide the same degree of accuracy and precision as the predicate device with simplified user interface and lighter, smaller, more portable housing to improve ease of use.

Phase I
Interventional
Diagnostic, Randomized, Open Label, Active Control, Single Group Assignment, Safety/Efficacy Study
  • Heart Failure
  • Dyspnea
  • Hypertension
  • Pacemaker
  • Trauma
Device: Noninvasive Hemodynamic Patient Monitor
 
 

*   Includes publications given by the data provider as well as publications identified by National Clinical Trials Identifier (NCT ID) in Medline.
 
Completed
25
June 2007
 

Inclusion criteria:

  • Age – 18-80 years
  • Weight – 80-300 pounds
  • Height – 5.0 feet – 6feet 4 inches Exclusion Criteria
  • Ongoing medical emergency or acute medical illness
  • NcIQ or ECG electrode adhesive allergy or sensitivity
Both
18 Years to 85 Years
Yes
Contact information is only displayed when the study is recruiting subjects
 
 
NCT00491777
 
NMT-IQ2/NcIQ
Noninvasive Medical Technologies, Inc.
  • University of Florida
  • Shand's Medical Center
Study Chair: Kevin Ferguson, MD Shand's Hospital
Principal Investigator: Joseph A Tyndall, MD Shand's Hospital
Study Director: David Seaberg, MD Shand's Hospital
Noninvasive Medical Technologies, Inc.
June 2007