28 mm Ceramic-on-Ceramic Acetabular Cup Total Hip Replacement Study
- Full Text View
- Tabular View
- Study Results
- Disclaimer
- How to Read a Study Record
| Tracking Information | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| First Received Date ICMJE | September 13, 2005 | ||||||||
| Last Updated Date | March 4, 2013 | ||||||||
| Start Date ICMJE | April 2003 | ||||||||
| Primary Completion Date | March 2008 (final data collection date for primary outcome measure) | ||||||||
| Current Primary Outcome Measures ICMJE |
Harris Hip Total Score [ Time Frame: 6 weeks, 6, 12 months and last follow up at 24 months or greater ] [ Designated as safety issue: No ] The Harris Hip scoring system assigns a numeric value to responses from patients and assessments made by a surgeon. A score of 91-100 is excellent, 81-90 is good, 71-80 is fair, 70 or below is poor. The patient records the following: pain level, need for assistance when walking, presence of a limp, distance able to walk, ability to put on shoes and socks, climb stairs, use public transportation and the length of time one is able to comfortably sit in a chair are all scored. |
||||||||
| Original Primary Outcome Measures ICMJE |
Success/Failure | ||||||||
| Change History | Complete list of historical versions of study NCT00208507 on ClinicalTrials.gov Archive Site | ||||||||
| Current Secondary Outcome Measures ICMJE |
Complication Rates [ Time Frame: On-going to end of study ] [ Designated as safety issue: Yes ] | ||||||||
| Original Secondary Outcome Measures ICMJE |
Harris Hip, Complication Rates | ||||||||
| Current Other Outcome Measures ICMJE | Not Provided | ||||||||
| Original Other Outcome Measures ICMJE | Not Provided | ||||||||
| Descriptive Information | |||||||||
| Brief Title ICMJE | 28 mm Ceramic-on-Ceramic Acetabular Cup Total Hip Replacement Study | ||||||||
| Official Title ICMJE | Delta Ceramax™ Ceramic-on-Ceramic Acetabular Cup Prosthesis Study (28mm) | ||||||||
| Brief Summary | The study is designed to evaluate artificial hips with a 28 mm ceramic head and a ceramic liner to determine whether they perform as well as artificial hips with a 28 mm ceramic head and a polyethylene liner. |
||||||||
| Detailed Description | Total Hip Arthroplasty (THA) is the surgical reconstruction of the hip joint through replacement of the femoral head and the acetabular articulating surfaces with fixed prosthetic devices. The goals of THA are relief from pain, restoration of function, and correction of deformity. THA is one of the most common adult reconstructive procedures. Over the past 25 years, patients who have needed to have their hip joint replaced, either due to trauma or arthritic disease, typically have had their hip joint bone articular surfaces replaced with a metal hip stem, metal ball head (either stainless steel or chrome cobalt) and a plastic acetabular cup (metal/metal/plastic). While the basic device has remained essentially unchanged over that period, technological advancements in implant designs and materials, and improvements in surgical technique and instrumentation have made THA one of the most durable and successful procedures in medicine. Reproducible, high-quality, short-term and mid-term results are attained regularly, and total hip replacements commonly last 10 to 15 years and longer. The success of this procedure has allowed its expansion into a wider, and often younger and more active population. In spite of the improvements in THA, little change has occurred for the acetabular cup liner, which is usually made out of Ultra High Molecular Weight Polyethylene plastic (UHMWPe). Because it is plastic and inherently soft and somewhat pliable under load, the cup's articular surface must inevitability wear and produce debris. This biologic response is now thought to be a significant contributor to prosthetic component loosening, a primary failure mode of THR. UHMWPe also degrades with time in the body. As concerns about polyethylene wear and the associated untoward effects of the generated wear debris, and as THA continues to be used in younger and higher-demand patients with increasing life expectancies, interest in ceramic on ceramic total hip prosthesis has been renewed. An alumina ceramic-on-ceramic acetabular coupling has been employed as an alternative to metal/polyethylene couplings. This ceramic-on-ceramic coupling has many advantages, including the elimination of polyethylene from the device system, wear rates that are appreciably less than those experienced with metal/polyethylene couplings and reduced biologic reactivity. The potential benefits of an alumina ceramic/ceramic bearing are significant. |
||||||||
| Study Type ICMJE | Interventional | ||||||||
| Study Phase | Phase 3 | ||||||||
| Study Design ICMJE | Allocation: Randomized Endpoint Classification: Safety/Efficacy Study Intervention Model: Parallel Assignment Masking: Single Blind (Subject) Primary Purpose: Treatment |
||||||||
| Condition ICMJE | Joint Diseases | ||||||||
| Intervention ICMJE |
|
||||||||
| Study Arm (s) |
|
||||||||
| Publications * | Not Provided | ||||||||
|
* Includes publications given by the data provider as well as publications identified by ClinicalTrials.gov Identifier (NCT Number) in Medline. |
|||||||||
| Recruitment Information | |||||||||
| Recruitment Status ICMJE | Completed | ||||||||
| Enrollment ICMJE | 264 | ||||||||
| Completion Date | December 2010 | ||||||||
| Primary Completion Date | March 2008 (final data collection date for primary outcome measure) | ||||||||
| Eligibility Criteria ICMJE | Inclusion Criteria:
Exclusion Criteria:
|
||||||||
| Gender | Both | ||||||||
| Ages | 20 Years to 75 Years | ||||||||
| Accepts Healthy Volunteers | No | ||||||||
| Contacts ICMJE | Contact information is only displayed when the study is recruiting subjects | ||||||||
| Location Countries ICMJE | United States | ||||||||
| Administrative Information | |||||||||
| NCT Number ICMJE | NCT00208507 | ||||||||
| Other Study ID Numbers ICMJE | COC 28 mm | ||||||||
| Has Data Monitoring Committee | No | ||||||||
| Responsible Party | DePuy Orthopaedics | ||||||||
| Study Sponsor ICMJE | DePuy Orthopaedics | ||||||||
| Collaborators ICMJE | Not Provided | ||||||||
| Investigators ICMJE |
|
||||||||
| Information Provided By | DePuy Orthopaedics | ||||||||
| Verification Date | March 2013 | ||||||||
|
ICMJE Data element required by the International Committee of Medical Journal Editors and the World Health Organization ICTRP |
|||||||||