Clinical Evaluation of Toric Intraocular Lens Made by Aurolab (TORICIOL)
- Full Text View
- Tabular View
- No Study Results Posted
- Disclaimer
- How to Read a Study Record
Purpose
The purpose of this study is to measure visual acuity and Intraocular Lens (IOL) rotational stability after implantation of TORIC IOL and to assess the post operative complications after implantation of TORIC IOL.
| Condition | Intervention | Phase |
|---|---|---|
|
Astigmatism |
Device: Experimental - Toric Intraocular lenses |
Phase 4 |
| Study Type: | Interventional |
| Study Design: | Endpoint Classification: Safety/Efficacy Study Intervention Model: Single Group Assignment Masking: Open Label Primary Purpose: Treatment |
| Official Title: | Clinical Evaluation of Toric Intraocular Lens Made by Aurolab |
- vision improvement [ Time Frame: 150 days ] [ Designated as safety issue: No ]The visual acuity will be measured after iol implantation on 1 day, 10 days, 40 days and 150 days post operatively
- Refractive error correction [ Time Frame: 150 days ] [ Designated as safety issue: No ]To measure the refraction error after IOL implantation on 1 day, 10 days, 40 days and 150 days post operatively
| Estimated Enrollment: | 120 |
| Study Start Date: | August 2011 |
| Estimated Study Completion Date: | June 2013 |
| Estimated Primary Completion Date: | May 2013 (Final data collection date for primary outcome measure) |
| Arms | Assigned Interventions |
|---|---|
|
Experimental: Single Arm
The enrolled subject will be implanted with Toric IOL manufactured by AuroLab
|
Device: Experimental - Toric Intraocular lenses
Toric Intraocular Lenses will be implenated with cataract patients having astigmatism
|
Detailed Description:
Among available methods for treating astigmatism in cataract surgery, the implantation of toric IOLs is an emerging technology that shows promising results. Similar to implanting a one-piece acrylic lens, toric IOLs provide good distance vision and, in many patients, freedom from spectacles for distance vision. A low absolute residual refractive cylinder has been associated with the implantation of toric IOLs, and the safety profile for toric IOLs has been good. As improvements with regard to rotational stability and treatment and cylinder power range are made, toric IOLs will emerge as an effective, safe treatment option for correcting astigmatism during cataract surgery.
Further, to evidence on the safety and efficacy of TORIC IOL for patients having cataract associated with astigmatism served as the basis for us to identify the published literature on the safety and efficacy of TORIC IOL implantation in the treatment of cataract associated with astigmatism, thus provide a background for the development of clinical investigation plan for the present study.
Eligibility| Ages Eligible for Study: | 40 Years to 65 Years |
| Genders Eligible for Study: | Both |
| Accepts Healthy Volunteers: | No |
Inclusion Criteria:
- Age 40 to 65
- Senile cataract
- Posterior Sub Capsular Cataract (PSCC)
- Astigmatism 1.25 D or more
- Residence within 100 kms of Madurai
Exclusion Criteria:
- Traumatic & Complicated cataract
- Poor mydriasis
- Amblyopia
- Severe Pseudo exfoliation (PXF)
- Dense posterior polar cataract (PPC)
- One eyed patients
- Uveitis
- Corneal pathology / Scar
- Retinal Pathology contributing to visual loss
- Intraoperative complication like PC rupture, Zonular dialysis
Contacts and Locations| Contact: Dr. Haripriya Aravind, MBBS., MS., | +91 452 4356100 ext 161 | haripriya@aravind.org |
| Contact: Mr. Mohamed Hussain, M.Pharm | +91 452 4356100 ext 364 | clinicalresearch@aravind.org |
| India | |
| Aravind Eye Hospital | Recruiting |
| Madurai, Tamilnadu, India, 625020 | |
| Contact: Dr. Haripriya Aravind, MBBS., MS +91 452 4356100 ext 161 drharipriya@aravind.org | |
| Contact: Mrs. Kamatchi Kannan, BA +91 452 4356100 ext 364 clinicaltrials@aravind.org | |
| Principal Investigator: | Dr. SHIVKUMAR CHANDRASHEKAR, MBBS., MS., | HOD of IOL & Cataract clinic, Aravind Eye Hospital, Tirunelveli |
More Information
No publications provided
| Responsible Party: | Aurolab |
| ClinicalTrials.gov Identifier: | NCT01396616 History of Changes |
| Other Study ID Numbers: | 1PN1011037 |
| Study First Received: | July 14, 2011 |
| Last Updated: | January 7, 2013 |
| Health Authority: | India: Ministry of Health |
Additional relevant MeSH terms:
|
Astigmatism Refractive Errors Eye Diseases |
ClinicalTrials.gov processed this record on May 23, 2013