Assessment of Digital Radiograph Measurements of Hip,Spine and Lower Limbs

The recruitment status of this study is unknown because the information has not been verified recently.
Verified October 2008 by Tel-Aviv Sourasky Medical Center.
Recruitment status was  Active, not recruiting
Sponsor:
Information provided by:
Tel-Aviv Sourasky Medical Center
ClinicalTrials.gov Identifier:
NCT00782223
First received: October 29, 2008
Last updated: NA
Last verified: October 2008
History: No changes posted
  Purpose

Research Protocol Assessment of Hip, Spine and Lower Limbs Digital Radiograph Measurements in Pediatric Population: using PACS integrated Computer Software (TraumaCad from OrthoCrat ™).

Introduction The integration of the PACS system into many medical institutions created a plethora of digital measurements to assess anatomic and deformity parameters for torso and limbs.

A number of commercial digital software is being offered to supply the medical practioner with tools to assess normal and pathological bony architecture land marks.

The relevant architecture of the pelvis (hip joint), spine and the length and alignment of lower limbs may be measured using these digital software's.

The validity and accuracy of digital work in comparison to conventional radiographs has been studied recently, mainly with lower extremity axial alignment, the digital length and anatomical angles measurements were found to be more reliable in terms of intra observer reliability than conventional radiographs (1, 2).

Study purposes

  1. To compare the, accuracy and reliability of specifically designed digital software (TraumaCad from OrthoCrat ™) measurements using wizard guidance, to those produced by using the tool bar (ruler and angle guide tools) of the DICOM folder.
  2. To assess intra and inter observer reliability of the TraumaCad software for different pediatric orthopaedics conditions.

    Methods *Twenty hip joins radiographs (AP views) of patients who suffer from Cerebral Palsy (10) and Developmental Dysplasia of the Hip (10) will be measured using the TraumaCad software hip joint wizard, and than again using basic tools of the DICOM folder.

    **Twenty spinal scoliosis radiographs (AP and Lat views) will be measured using the TraumaCad software templates.

    ***Ten digital radiographs of long leg standing (AP views) from normal and from patients with deformities will ne analyzed for length and angular differences using the LLD wizard.

    The following parameters will be measured *Hip joint radiographs: Acetabular Angle, Central Edge Angle, and Reimer's Index **Spinal radiographs: Cobe Angle (AP views), Coronal Balance, Sagital Balance. ***Long standing views: length of Femur and Tibia, mLDFA, mMPTA, mLDTA, JLCA, (the "Baltimore numbers").

    All measurements will be taken by 4 senior orthopaedic surgeons after consensus conference for the technique.

    Intra observer reliability will be tested by repeating the same set of measurements on 2 different dates, after all radiographs are randomly mixed and done at least 2 days apart. High resolution single computer will be used for all measurements by all participating surgeons.

    The intra and inter observer reliability for the hip joint measurements will be calculate to compared between TraumaCad software wizard and the DICOM measurements tools.

    All measurements using TraumaCad software will be analyzed for intra and inter observer reliability using accepted statistical tools.

    The study will be supervised by the department of statistics of TAU for maximum statistical significance.

1) Sailer J, Scharitzer M, Peloschek P, Giurea A, Imhof H, Grampp S.

Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs.

Eur Radiol. 2005 Jan; 15(1):170-3. Epub 2004 Aug 5.

2) Hankemeier S, Gosling T, Richter M, Hufner T, Hochhausen C, Krettek C.

Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method.

Comput Aided Surg. 2006 Mar; 11(2):81-6


Condition
Healthy

Study Type: Observational
Study Design: Observational Model: Cohort
Time Perspective: Prospective
Official Title: Assessment of Hip, Spine and Lower Limbs Digital Radiograph Measurements in Pediatric Population: Using PACS Integrated Computer Software (TraumaCad From OrthoCrat)

Resource links provided by NLM:


Further study details as provided by Tel-Aviv Sourasky Medical Center:

Estimated Enrollment: 50
Study Start Date: July 2008
Estimated Primary Completion Date: December 2008 (Final data collection date for primary outcome measure)
Groups/Cohorts
1
Hip X-rays DDH
2
Hip X-rays, CP
3
Long standing lower Limb X-rays
4
Scoliosis, AP X-rays
5
Scoliosis Lateral X-rays

  Eligibility

Ages Eligible for Study:   2 Months to 30 Years
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   No
Sampling Method:   Non-Probability Sample
Study Population

Digital X-rays from PACS system

Criteria

Inclusion Criteria:

  • hip, long leg & spine digital X-rays

Exclusion Criteria:

  • inadequate X-rays
  Contacts and Locations
No Contacts or Locations Provided
  More Information

No publications provided

Responsible Party: Tel-Aviv Sourasky Medical Center
ClinicalTrials.gov Identifier: NCT00782223     History of Changes
Other Study ID Numbers: 0135-08-TLV
Study First Received: October 29, 2008
Last Updated: October 29, 2008
Health Authority: Israel: Ministry of Health

Keywords provided by Tel-Aviv Sourasky Medical Center:
hips, spine, lower limb, digital radiograph measurements, TraumaCad, digital software
Measurements of orthopaedic parameters on digital X-rays using particular software