  Purpose

The purpose of this research study is to evaluate a better way of diagnosing heart artery disease, heart attack and damage to the heart muscle early on. Currently, it often takes several hours after admission before lab tests will show that there has been any damage to the heart muscle. Although the standard electrocardiogram is quick and non-painful it may miss many cases of significant coronary heart disease. The investigators are proposing that a new entirely non-contact tool, the Magnetocardiograph (MCG), with high accuracy is able to predict the presence of significant coronary heart disease early on before other studies become positive. The investigators hope by this that the investigators can develop an algorithm for better triage and management of patients with chest pain.

This research study is designed to test the effectiveness of the investigational use of the Magnetocardiograph (MCG) that has been approved by the U.S Food and Drug Administration (FDA). While the MCG used in the study is FDA-approved as a tool for the non-contact measurement and display of the magnetic fields of the heart generated by the electrical currents, it is not yet approved for the specific diagnosis of heart artery disease (ischemia).


Condition
Chest Pain

Study Type: Observational
Study Design: Observational Model: Cohort
Time Perspective: Prospective
Official Title: Magnetocardiography (MCG) in the Diagnosis of Chest Pain Syndrome

Resource links provided by NLM:


Further study details as provided by Cedars-Sinai Medical Center:

Estimated Enrollment: 398
Study Start Date: October 2004
Estimated Study Completion Date: December 2009
Estimated Primary Completion Date: December 2009 (Final data collection date for primary outcome measure)
Groups/Cohorts
1
Patients with chest pain syndrome

Detailed Description:

Cardiomagnetism refers to the detection, analysis and interpretation of the magnetic fields generated by the electrical activity of the heart. The peak value of the magnetic fields of the heart is more than a million times smaller than the Earth's magnetic field. A major breakthrough in the capability of measuring such small fields came with the invention of the SQUID (superconducting quantum interference device) in the late sixties. The first magnetocardiograms (MCGs) measured with the SQUID were recorded by Cohen et al. in 1970 (1). These earlier measurements were performed in very expensive magnetically shielded rooms, initially utilizing only one or two SQUID probes. In the eighties this technology was tested in several laboratories creating a magnetic field map by moving one SQUID sequentially above the chest to create an image of the whole hearts magnetic field. These maps were then attempted correlated with various pathologies (2,3).

Since then the technology has been greatly improved and several multichannel machines are in use across the world for research purpose for arrhythmia localization and ischemia detection. However, at present time, only one company (CardioMag Imaging) has developed a machine that operates outside a shielded room.

The CardiomagImaging (CMI) Magnetocardiograph (MCG) is capable of noninvasive recording of magnetic fields arising from the electrical activity of the heart with very high spatial and temporal resolution. The temporal trace of the MCG is analogous to an ECG, and, similarly, can be recorded in multiple leads. This MCG device has been specifically developed for the general purpose (outside shielded room) of non-contact, non-invasive diagnostics of ischemia.

The CMI MCG device has been approved as safe for patients. It is FDA approved for the noninvasive detection and display of the heart's magnetic field created by the electrical currents, and is awaiting FDA approval for the detection of ischemia in chest pain patients. A similar SQUID technology utilized in magnetically shielded rooms has already been FDA approved for localization of epileptic focus. When utilized in this matter it is referred to as MEG (magnetoencephalogram).

Several abstracts have been presented primarily at meetings on Biomagnetism, that confirm the safety and indicate the efficacy of the MCG for the detection of ischemia. In particular, it has been suggested that the resting MCG is capable of detecting ischemia in patients with chest pain, when the 12-leads ECG is normal (4,5,6). However, this has not been tested in larger prospective blinded studies.

Cedars-Sinai Medical Center Non-invasive Cardiac Laboratory will be the first center in the US evaluating the CardioMag Imaging MCG in a clinical environment for the detection of ischemia in an acute coronary syndrome patient population. Patients will be enrolled in a similar protocol at Johns Hopkins Medical Center, Baltimore, Mayo clinic, Rochester, and at Klinikum Hoyerswerda, Germany. The early detection of ischemia (before Troponins become positive) with high negative and positive predictive values may prove cost effective and decrease risk by improving prompt treatment and triage to higher or lower grade monitoring at time of hospitalization.

  Eligibility

Ages Eligible for Study:   18 Years and older
Genders Eligible for Study:   Both
Accepts Healthy Volunteers:   Yes
Sampling Method:   Probability Sample
Study Population

Patients with chest pain syndrome

Criteria

Inclusion Criteria:

  • Patients with chest pain syndrome

Exclusion Criteria:

  • ST elevation MI
  • Hemodynamically unstable patients
  • Tachycardia with heart rate >150 just prior to testing or at time of testing
  • A-V Dissociation on 12-lead ECG
  • Patients with pacemakers or internal defibrillators
  • Minors < 18 years of age
  • Patients unable to lie flat for the examination
  Contacts and Locations
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the Contacts provided below. For general information, see Learn About Clinical Studies.

Please refer to this study by its ClinicalTrials.gov identifier: NCT00572949

Locations
United States, California
Cedars-Sinai Medical Center
Los Angeles, California, United States, 90048
Sponsors and Collaborators
Cedars-Sinai Medical Center
CardioMag Imaging
Investigators
Principal Investigator: Kirsten Tolstrup, MD Cedars-Sinai Medical Center
  More Information

Publications:
1) Cohen D, Edelsack EA, Zimmerman JE. Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer. Appl. Phys. Lett. 1970, 16, 278-280.
3) Stroink G, MacAuley C, Montague TJ, Horacek BM. Normal and abnormal components in magnetocardiographic maps of a subject with myocardial infarction. Med. Biol. Eng. Comp. 1985, 23, 61-62.
4) Brazdeikis A, Taylor AA, Mahmarian JJ, Xue Y, Chu CW. Comparison of magnetocardiograms acquired in unshielded clinical environment at rest, during and after exercise and in conjunction with myocardial perfusion imaging. Biomag 2002, 530-532.
5) Chaikovsky I, Primin M, Nedayvoda I, Vassylyev V, Sosnitsky V, Steinberg F. Computerized classification of patients with coronary artery disease but normal or unspecifically changed ECG and healthy volunteers. Biomag 2002, 534-536.
6) Morguet AJ, Koch H, Behrens S, Kosch O, Godde P, Lange C, Selbig D, Munz DL, Schultheiss HP. Magnetocardiography to assess myocardial viability in patients with coronary heart disease. Biomag 2002, 540.

Responsible Party: Kirsten Tolstrup,MD, Cedars-Sinai Medical Center
ClinicalTrials.gov Identifier: NCT00572949     History of Changes
Other Study ID Numbers: 4039
Study First Received: December 12, 2007
Last Updated: November 16, 2009
Health Authority: United States: Institutional Review Board

Keywords provided by Cedars-Sinai Medical Center:
heart disease
chest pain
coronary artery disease
atherosclerosis

Additional relevant MeSH terms:
Chest Pain
Pain
Signs and Symptoms

ClinicalTrials.gov processed this record on July 24, 2014